(2) Switching power supply for indoor unit
Fig. 4-3 shows the switching power supply circuit for the indoor units.
Input voltage after
rectification, approx.
325V DC
It is supplied via
CN1 from control
P.W.B..
The switching power supply circuit consists 2 circuits , and is carried on the SW-D-P.W.B.
The circuit for A cycle generates 35V of the power supply voltage for the indoor unit 1¥ 2, and 12V and 5V for the drive of
electric expansion valve. Similarly . the circuit for B cycle generates 35V of the power supply voltage for the indoor unit 3 ¥ 4,
and 12V and 5V for the drive of B cycle electric expansion valve. The voltage specification of each output is in fig . 4-2 below.
Fig . 4-2 Voltage specification.
Output name
35 V A
BEN 12V A
BEN 5V A
35V B
BEN 12V B
BEN 5V B
3A, fuse
Fig. 4-3 Switching power supply circuit for indoor unit
Output specification
35 (± 2.5) V
12 (± 2.0) V
5 (± 0.5) V
35 (± 2.5) V
12 (± 2.0) V
5 (± 0.5) V
SW transformer 2
SW transformer 3
Main load circuit
Indoor unit 1 ¥ 2, Reversing valve for A cycle
Electric expansion valve 1 ¥ 2 for A cycle
Control circuit for electric expansion valve of A cycle
Indoor unit 3 ¥ 4 (only unit 3 operates for 3 rooms)
Electric expansion valve 1 ¥ 2 for B cycle
Control circuit for electric expansion valve of B cycle
220
A cycle
B cycle