FSA 450
...11.
Software
11.2.4 Trigger sources
Channels 1 through 4 – Oscilloscope
inputs
Trigger – Sync Probe (inductive trigger
clamp)
Secondary 1 – Single Ignition lead input
or Red spider lead input
Secondary 2 – Black spider lead input
Primary Ignition – Primary Ignition input
Expansion 1 – AC signal from Vacuum
Probe (Auxiliary Input)
Expansion 2 – DC signal from Vacuum
Probe or Pressure Transducer (Auxiliary
Input)
11.2.5 Pre-trigger percentage
0-100%
11.2.6 Measuring system cursor selection
Delta value between horizontal or vertical
cursors
Voltage difference measurement
Time difference measurement
Vacuum/Pressure difference measurement
11.2.7 Scope pre-selects
Preset
configurations
component measurements
Example
waveforms
components
11.2.8 Record and storage functions
Record and Playback movie of displayed
screens
User selectable record time
Save and Recall display screens
11.2.9 Measuring functions
0.05 Volts/div to 50 Volts/div
20 μ−seconds/div to 20 seconds/Div
Voltage
Offset;
between bottom and top of grid
Robert Bosch GmbH
for
various
of
known-good
channels
adjustable
11.2.10 Pressure transducer
Engine Analyzer Display Range: 1 psi/div
to 100 psi/div
Selectable Ranges:
-
8 psi - 300 psi
11.2.11 AC vacuum (vacuum probe)
Engine Analyzer Display Range: 0.1 inHg/
div to 2 inHg/div
Selectable Ranges:
-
0.8 inHg - 16 inHg
11.2.12 DC vacuum (vacuum probe)
Engine Analyzer Display Range: 0.5 psia/
div to 20 psia/div
Selectable Ranges:
-
4 psia - 30 psia
11.2.13 High current probe
Engine Analyzer Display Range: 1 Amp/
div to 500 Amps/Div
Selectable Ranges:
-
8 Amps - 1000 Amps
11.2.14 Low current probe
Engine Analyzer Display Range:
0.05 Amps/div to 10 Amps/Div
Selectable Ranges:
-
400 mAmps - 30 Amps
EN | 37
1 689 979 945 (28.07.2006)