Optional Remote Line Adaptor: (continued from page 21)
4) Before hooking up the air supply to the Remote Coil, markers with remote
line adaptor must first have an empty 12 gram CO2 cartridge installed to oper-
E
ate properly. ❏ Turn off the remote coil air flow control valve
control
counterclockwise
N
gram CO2 cartridge
G
tion instructions on page 6. ❏ Empty the cartridge of any air - follow To Unload
a marker with a PUNCTURED air cartridge on page 13 (then keep the empty
L
cartridge installed).
I
5) To install the air supply cylinder
S
cylinder valve if necessary (see Warning below). ❏ Lubricate the cylinder
valve O-ring with a little marker grease, then insert the cylinder valve end into
H
the air supply adapter of the remote coil. Twist the cylinder clockwise into the
adapter
until it stops. Your marker is ready to fire once you turn the flow
control
(clockwise all the way in
and switch to Fire Mode from Safe Mode. NOTE: If the cylinder is full, and
you do not hear the air supply engage, the pin valve could be
too short or the pin valve seal is damaged (follow the Air Supply
Cylinder Removal from the Remote Coil instructions on pages
21-22). To turn off air supply: turn flow control
out. To turn on air supply: turn flow control completely in.
6) Air Supply Cylinder Removal
Step1) You must first read the following Air Supply Cylinder
WARNINGS and SAFETY TIPS before beginning the cylinder removal in
step 2 on page 24).
WARNING
NEVER UNSCREW
THE CYLINDER
THE BRASS OR NICKEL PLATED VALVE
INTENDED TO BE PERMANENTLY ATTACHED TO
THE AIR OR CO2 CYLINDER
CYLINDER CAN FLY OFF WITH ENOUGH FORCE
TO CAUSE SERIOUS INJURY OR DEATH IF THE
CYLINDER
UNSCREWS
There have been reported incidents that were caused by players un-
knowingly unscrewing the cylinder
occurs when the player thinks the entire valve-cylinder assembly is being
unscrewed from the air adaptor or a paintball marker
are unscrewing the cylinder
. To Avoid This Danger: It is recommended, if your
cylinder is not already marked, that you use paint or
nail polish to place a mark
place a mark
on the cylinder as shown.
out until it stops (see below). ❏ Install a 12
: follow STEP 1: Air Supply Cartridge Installa-
: ❏ First mark the cylinder and
), remove the barrel blocking device,
completely
FROM THE CYLINDER VALVE
IS
. AN AIR OR CO2
FROM A CYLINDER VALVE
.
from the cylinder valve
when in fact they
from the cylinder valve
on the cylinder valve and
Air Supply Cylinder Removal from
22
Remote Coil: (continued on page 23)
Air Supply Cylinder Removal from Remote Coil: (continued from page 22)
Whenever you turn the cylinder
the cylinder and the mark
: turn the flow
together. If at any time these
marks start to separate
as shown,
is starting to unscrew
from the cylinder valve
and you should STOP and
take the entire unit to a C5
certified airsmith for safe
removal and/or repair.
NOTE: The cylinder valve should unscrew from the air adapter or paintball
marker in about 3 or 4 full turns. If you finish the 4
valve is not unscrewed from the air adapter or paintball marker, STOP! Take
the entire unit to a C5 certified airsmith for safe removal and/or repair. ❏
Locate a "C5" Certified Airsmith at www.paintball-pti.com/search.asp
Whether you have a new or used refillable Air or CO
if any of the following has occurred: ❏ The valve unit was replaced or altered
after purchase. ❏ An anti-siphon device was installed. ❏ The valve unit was
removed from the cylinder for any reason. ❏ Any modification was done to
the refillable Air or CO
your air or CO
the cylinder manufacturer.
SAFETY TIPS to ensure that your Air or CO
• Improper use, filling, storage or disposal of Air or CO
in property damage, serious personal injury or death.
.
• Make sure that any maintenance or modification to any Air or CO
cylinder is done by a qualified professional, such as a C5 certified
airsmith.
• The use of anti-siphon devices is not recommended. However, if one
is already installed on your Air or CO
that your cylinder be checked by, or the device installed by, a qualified
professional.
. This
• All Air or CO
• Cylinder valves must be installed only by properly trained personnel.
• Do not overfill!! Never exceed the Air or CO
• Do not expose pressurized Air or CO
130 degrees Fahrenheit ( 55 degrees Celsius ).
• Do not use caustic cleaners or strippers on the Air or CO
valve and do not expose to corrosive materials.
• Do not modify the Air or CO
disassemble the tank valve from the Air or CO
during removal, watch the mark
on the cylinder valve to be sure that they rotate
Remote coil
the cylinder
air supply
adapter
cylinder. If any of these conditions has occurred take
2
cylinder to a "C5" Certified Airsmith for inspection or contact
2
2
cylinder or is desired, it is critical
2
cylinders must be filled only by properly trained personnel.
2
2
cylinder to temperatures exceeding
2
cylinder in any way. Never try to
2
Air Supply Cylinder Removal from Remote Coil:
23
on
E
N
STOP
G
L
I
S
H
full turn and the cylinder
th
cylinder, you are at risk
2
cylinder is safe for play:
cylinder may result
2
2
cylinder's capacity.
cylinder or tank
2
cylinder.
2
(continued on page 24)