Example, in order to link a pair [remote control serial number + key number] to an output, you must: select the
output with «Sel0» and «Sel1», set «Add/Remove» to «0», then press the remote control key. If the link already
exists in the receiver's database, this operation will cause it to disappear from the database.
Erase: when level '0' is assigned to this input, this erases all the pairs [serial number + key] from the database for
an output chosen with the pins «Sel0» and «Sel1». After this operation, the chosen output is no longer controlled
by any remote control. For security reasons, this operation is carried out after receipt of a valid message from
any remote control.
Note: association of a command with the «Global» pin.
Enabling the «Global» input (application of level «0») changes the behaviour of the Add/Remove and Erase
commands as follows:
Add/Remove command:
If the remote control used (the key does not matter) controls at least one output on the receiver, all the asso-
ciations for this remote control are removed: this remote control no longer controls any outputs.
If the remote control used does not control an output, the following associations are created:
Key 1 controls output 1, key 2 controls output 2, key 3 controls output 3 and key 4 controls output 4.
Erase command: all the associations in the receiver's memory are erased. The outputs are no longer controlled
by any remote-control.
Some important behaviours during the training phases:
all the keys pressed on the remote control are sent on the serial link.
the receiver operates in training mode if one of the «Add/Remove» or «Erase» inputs is set to logic
'0' or if one of the AT registers (ATS801, ATS802, ATS803, ATS804, ATS805) is set to a value other
than 0.
"Add/Remove" and "Erase" must not be simultaneously set to «0».
AT commands have priority over switch inputs. If one of the AT commands (ATS801, ATS802, ATS803,
ATS804, ATS805) is set to a value other than 0, the switch inputs are ignored.
The following tables summarise the training mode options and the procedure for creating associations between
serial number + key pairs and the digital outputs.
ADD/REMOVE for a chosen relay
(see below the restrictions for 8/24 key remote controls)
With command and selection inputs
1/ Select «Add/Remove» mode by setting the Add/
Remove input to «0».
2/ Make sure that «Global» and «Erase» are not
enabled.
3/ Select the output that the remote control needs to
control by setting «Sel0» and «Sel1».
4/ Press the remote control key that will be used to
control the chosen output.
5/ Exit «Add/Remove» mode by setting the Add/
Remove input to «1».
Two results are possible with this operation:
This association had not been set up previously. The association is now created. The LED flashes
once.
This association had been set up previously. The association is erased. The LED flashes twice.
Gamme ARF18 UG V1.5
With AT commands
1/ Enter one of the following AT commands:
ATS801=2 to choose output 1
ATS802=2 to choose output 2
ATS803=2 to choose output 3
ATS804=2 to choose output 4
2/ Press the remote control key that will be used to
control the chosen output.
3/ Exit «Add/Remove» mode by setting the ATS80x
register used to «0».