Pin name
Sel0 and Sel1
Global
Digital output 1
Digital output 2
Digital output 3
Digital output 4
Gamme ARF18 UG V1.5
Direction
Description
When the module is in training mode, ("Add/Remove" or "Erase" in logic
'0'), "Sel0" and "Sel1" select the output to be configured:
Input
When the module is not in training mode, input "Sel0" selects the type
of functionality of digital outputs 1 and 2, and "Sel1" the type of functio-
nality of digital outputs 3 and 4.
logic '0' on "Sel0": digital outputs 1 and 2 in bistable mode.'
logic '0' on "Sel1": digital outputs 3 and 4 in bistable mode.'
logic '1' on "Sel0": digital outputs 1 and 2 in monostable mode.'
logic '1' on "Sel1": digital outputs 3 and 4 in monostable mode.'
The global input is used to determine whether the training operation is
carried out or not for several digital outputs.
Logic '0' on "Global": the training operation is carried out for seve-
Input
ral outputs (inputs «Sel0» and «Sel1» are ignored). Functionality
depends on the function chosen («Erase» or «Add/Remove»).
Logic '1' on "Global": the training operation only applies to the digital
output chosen with 'Sel0' and 'Sel1'.
Output
This output is one of the four outputs controlled by the module when a
signal is received from a remote control saved for this output.
Output
This output is one of the four outputs controlled by the module when a
signal is received from a remote control saved for this output.
Output
This output is one of the four outputs controlled by the module when a
signal is received from a remote control saved for this output.
Output
This output is one of the four outputs controlled by the module when a
signal is received from a remote control saved for this output.
Sel 1
Sel 0
Digital output chosen
0
0
4
0
1
3
1
0
2
1
1
1