1.28 Flange Socket 16 A; Flange Socket 32 A - Eaton CROUSE-HINDS Série Mode D'emploi

Masquer les pouces Voir aussi pour CROUSE-HINDS Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dimensions in mm
X = fixing dimensions
Flange socket
2-pol� + PE
Flange socket
4/5-pol�/ + PE
Code Zone 1
2 pol� + PE
3 pol� + PE 3 pôl� + N + PE
Dimensions in mm
X = fixing dimensions
Flange socket
3-pol�/ + PE
Flange socket
4-pol�/ + PE
Code Zone 1
3 pol� + PE
3 pôl� + N + PE
44
Explosion-protected distributions GHG 619

1.28 Flange socket 16 A

EC type examination certificate:
Marking acc� to 2014/34/EU and standard
EN 60079-0
IECEx type examination certificate:
Category of application:
IEC 60079-0
Rated voltage:
GHG 511 -
3-pole
GHG 511 -
4-pole
GHG 511 -
5-pole
(Special voltages and various contact-marking are possible on request)
Rated curret:
Back-up fuse:
without thermal protection
with thermal protection
Switching capacity AC 3 3-pole:
Switching capacity AC 3 4-pole:
Switching capacity AC 3 5-pole:
Perm� ambient temperature:
Protection category acc� to IEC/EN 60529
with closed and secured hinged cover as well
as combinations properly plugged together
Supply terminal
Flange socket GHG 511
Test torques:
Terminals
Weight:
Flange socket
3-pole GHG 511 83
Flange socket
4-pole GHG 511 84
Flange socket
5-pole GHG 511 85
Auxiliary contact, rated voltage:
Auxiliary contact, rated current:
1.29

Flange socket 32 A

EC type examination certificate:
Marking acc� to 2014/34/EU and standard
EN 60079-0
IECEx type examination certificate:
Category of application:
IEC 60079-0
Rated voltage:
GHG 512 -
(Special voltages and various contact-marking are possible on request)
Rated curret:
Back-up fuse:
without thermal protection
with thermal protection
Switching capacity AC 3 5-pole:
Perm� ambient temperature:
Protection category acc� to EN/IEC 60529
with closed and secured hinged cover as well
as combinations properly plugged together
Supply terminal
Flange socket GHG 512
Test torques:
Terminals
Weight:
Flange socket
4-pole GHG 512 84
Flange socket
5-pole GHG 512 85
Auxiliary contact, rated voltage:
Auxiliary contact, rated current:
PTB 99 ATEX 1040 U
D II 2 G Ex de II C
D II 2 D Ex tD A21 IP 66 T 80 °C
IECEx BKI 04�0002
Ex de II C
Ex tD A21 IP 66 T 80 °C
up to 415 V, 50/60 Hz
up to 690 V, 50/60 Hz
up to 500 V, 50/60 Hz
max� 16 A
25A
35A gG
250 V/16 A
400 V/16 A
500 V/16 A
-20 °C to +40 °C (catalogue version)
Special versions permit deviating temperatures�
IP 66 (catalogue version)*
Cross section
Stripped wire length
2 x 1�5 - 4�0 mm
10 mm
2
2�5 Nm
(catalogue version)
approx� 0�38 kg
approx� 0�53 kg
approx� 0�58 kg
250 VAC
AC / 5 A
DC / 0�03 A
PTB 99 ATEX 1042 U
D II 2 G Ex de II C
D II 2 D Ex tD A21 IP 66 T 80 °C
IECEx BKI 04�0006
Ex de II C
Ex tD A21 IP 66 T 80 °C
up to 690 V, 50/60 Hz
max� 32A
35 A
50 A gG
690 V/32 A
-20 °C to +40 °C (catalogue version)
Special versions permit deviating temperatures�
IP 66 (catalogue version)*
Cross section
Stripped wire length
2 x 4�0 - 10�0 mm
12 mm
2
2�5 Nm
(catalogue version)
approx� 1�00 kg
approx� 1�05kg
250 VAC
AC / 5 A
DC / 0�03 A
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ghg 619

Table des Matières