12 Equipment Data

Equipment Data for Air-to-Water Heat Pumps for Heating
1
Type and Commercial Description
2
Model
2.1
Type
2.2
Enclosure type acc. to EN 60 529
2.3
Installation site
3
Performance Data
3.1
Operating temperature limits:
Heating water supply / return
Air (heat source)
3.2
Temperature spread
of heating water according
3.3
Heating capacity / coeff. of perform at A2 / W35
3.4
Sound power level
3.5
Sound pressure level at 10 m distance (discharge side)
3.6
Heating water flow with an internal pressure differential
3.7
Free pressure, heating circulating pump (max. stage)
3.8
Refrigerant; total charge weight
3.9
Output of electric heating element adjustable
(heat exchanger 2)
4
Dimensions, Connections and Weight
4.1
Equipment dimensions
4.2
Equipment connections for heating
4.3
Weight of transport unit(s) incl. packaging
5
Electrical Connection
5.1
Nominal voltage; fusing
5
5.2
Heat element fuse
5.3
Starting current with soft starter
5.4
Nominal power consumption
Nominal current A7 / W35 / cos ϕ
5.5
6
Complies with European Safety Regulations
7
SOther Design Characteristics
7.1
Defrosting
Defrost type
Defrost pan available
7.2
Heating water inside unit protected against freezing
7.3
Performance settings
7.4
Controller internal/external
1. For outside air between -20° C to 0° C, flow temperature increasing from 49° C to 58° C.
2. This data indicates the size and capacity of the system according to EN 255 and EN 14511. For economic and energetic considerations, additional factors such as defrosting
behaviour, bivalence point and control need to be taken into account. Abbreviations have the following meaning: e.g. A7 / W35: outside temperature 7 °C and heating water supply
temperature 35 °C.
3. Recommended heating water flow rate
4. minimum heating water flow rate
5. To establish an electrical connection for the heating element, a special mains cable with separate fuse is required.
6. See CE Declaration of Conformity
7. The heating circulating pump and the controller of the heat pump must be on standby at all times.
www.dimplex.de
1
°C / °C
°C
at A7/W35
K
2
kW / ---
2
at A7 / W35
kW / ---
2
at A7 / W45
kW / ---
2
at A10 / W35
kW / ---
2
at A-7 / W35
kW / ---
dB(A)
dB(A)
m³/h / Pa
Pa
type / kg
kW
H x B x L mm
inch
kg
V / A
A
A
2
A7 / W35
kW
A / ---
LAK 10M
Compakt
IP 24
Outdoors
Up to 58 +/- 2 / above 18
-20 to +35
10.9
8.1 / 3.4
10.2 / 4.1
11.5 / 4.5
72
46
3
0.8
/ 1100
1.65
65000
R404a / 2,3
2.4 max. 6
880 x 1285 x 695
G 1'' external
185
230 / 25
30
32
2.5
13.6 / 0.8
6
automatic
cycle reversal
yes (heated)
7
yes
1
internal
12
5.0
8.0 / 3.2
9.7 / 3.8
8.7 / 3.1
10.9 / 4.2
5.6 / 2.5
4
/ 4500
60000
2.6
14.1 / 0.8
E-9