The following table illustrates the torque requirements for the field wiring connectors :
Le tableau suivant indique les spécifications de couple pour les connecteurs de câblage sur site:
Connector
MKD-C X12
MKD-C X13
MKD-C X14
MKD-C X20A/B
MKD-C X25
MKD-N X29A/B (6A/12A)
MKD-N X29A (24A/48A)
MKD-N X30A (24A/48A)

8.5.2 Conformance with REACH

EU Regulation no. 1907/2006 deals with the registration, evaluation, authorization and
restriction of chemical substances 1 (abbreviated to "REACH").
The device does not contain any substances (CMR substances, PBTsubstances, vPvB
substances and similar hazardous substances stipulated in individual cases based on
scientific criteria) above 0.1 mass percent per product that are included on the candidate list.

8.5.3 Conformance with EU Low Voltage, EMC and RoHS Directives

EU Declarations of Conformity can be found on the
The devices have been tested by an authorized testing laboratory in a defined configuration,
using the system components that are described in this documentation. Any divergence from
the configuration and installation described in this documentation means that the user will be
responsible for carrying out new measurements to ensure conformance with regulatory
requirements.
Kollmorgen declares the conformity of the MKD modules with the following directives:
EC Directive 2014/35/EU, Low Voltage Directive
Used harmonized standard EN 61800-5-1
EC Directive 2014/30/EU, EMC Directive
Used harmonized standard EN 61800-3
EC Directive 2011/65/EU with delegated directive 2015/863/EU, RoHS Directive
Used harmonized standard EN 50581
System MKD-C with MKD-N
MKD-C must be powered from a 3 phase industrial supply network via a mains choke 3L.
The MKD modules meet the noise immunity requirements to the 2nd environmental
category (industrial environment).
For noise emission the MKD system modules meet the requirement to a product of the
category C2 (motor cable up to 10 m). With a motor cable length of 10 m or more, the
system meets the requirement to the category C3.
These devices can cause high-frequency interferences in non industrial environments and
may require measures for interference suppression (additional external EMC filters).
MKD Product Safety Guide | 8   Appendix
Torque / Couple serrage
30.9 - 39.8 lb-in (3.5 - 4.5 Nm)
6.2 - 7.1 lb-in (0.7 - 0.8 Nm)
2.6 - 6.2 lb-in (0.3 - 0.7 Nm)
2.6 - 6.2 lb-in (0.3 - 0.7 Nm)
2.6 - 6.2 lb-in (0.3 - 0.7 Nm)
6.2 - 7.1 lb-in (0.7 - 0.8 Nm)
2.6 - 6.2 lb-in (0.3 - 0.7 Nm)
2.6 - 6.2 lb-in (0.3 - 0.7 Nm)
Kollmorgen Developer
Kollmorgen | kdn.kollmorgen.com | September 2019
Wire size / Section de fil
2 awg (35 mm²)
10 awg (6 mm²)
8 awg (10 mm²)
10 awg (6 mm²)
6 awg (16 mm²)
10 awg (6 mm²)
6 awg (16 mm²)
16 awg (1.5 mm²)