Weedkillers
Natural oils dissolved in water (e.g..neem oil,
rapeseed oil)
Fertilizers dissolved in water
The solution to be sprayed must be approved by
its manufacturer for distribution using a spraying
unit. Arrange to be shown how to use the unit sa-
fely if you are not familiar with it.
Liquids to be sprayed, particularly natural oils dis-
solved in water, must have a water-like consisten-
cy. Liquids of greater viscosity cannot be sprayed,
or only with lesser power.
Only liquid fertilizers, weedkillers and pesticides
that are approved by the local licensing autho-
rity in the country of use may be sprayed. At the
time of manufacture, no harmful eff ects on the
materials used are known to be caused by these
approved substances or natural oils dissolved in
water. The fertilizers, pesticides and weedkillers
are only allowed to be sprayed in the concentra-
tions specifi ed by the manufacturer of the spray
solutions. If in doubt, please contact the relevant
manufacturer.
The pressure sprayer is not designed to be used
with foodstuff s or to spray liquids that exceed
the maximum permitted operating temperature
of 40°C. Similarly, it is prohibited to spray acidic,
caustic and fl ammable liquids whose fl ash point
is below 55 °C, as well as impregnating agents,
disinfectant, paints, varnishes, grease, glazes and
synthetically manufactured oils.
Important! Atomized fl ammable liquids with a
fl ash point in excess of 55 °C are also highly com-
bustible.
Never use the pressure sprayer
as a flame gun
for storing liquids
for substances with unknown risk.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
Anl_GE_WS_18-150_Li_SPK9.indb 23
GB

4. Technical data

Power supply: ......................................... 18 V DC
Pump type: .............................. Membrane pump
Tank capacity approx.: ...................................17 l
Filling capacity max.: ......................................15 l
Delivery rate: ....................................... 54-102 l/h
Spray pressure: ........................... 4.5 bar (65 psi)
Nozzle Ø: ................................................ 1.7 mm
Optimal spraying distance: ......................... 0.5 m
Technical residual quantity: .......................100 ml
Permissible maximum operating temperature:
................................................................. + 40 °C
Spray tube length with connector/nozzle: ...60 cm
Weight when empty: ...................................4.7 kg
Weight when full: ......................................19.7 kg

Important!

The equipment is supplied without batteries and
without a charger and is allowed to be used only
with the lithium-ion batteries of the Power-X-
Change series!
The lithium-ion batteries of the Power-X-Change
series are allowed to be charged only with the
Power-X-Charger.
Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with Annex I, EN 62841-1.
L
sound pressure level ..................... 60.3 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level ....................... 71.3 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Total vibration values (vector sum of three direc-
tions) determined in accordance with Annex I, EN
62841-1.
Handle
Vibration emission value a
K uncertainty = 1.5 m/s
The stated vibration emission levels and stated
noise emission values were measured in ac-
cordance with a set of standardized criteria and
can be used to compare one power tool with
another.
- 23 -
= 2.12 m/s
2
h
2