Providing a breath sample

1. Remove the handset from
the holster.
2. If necessary, insert a new
mouthpiece
into
respective
opening.
When
doing so, ensure that the
mouthpiece tab is correctly
aligned with the slot in the
handset (1).
3. Blow evenly into the mouth-
piece as long as a continuous
tone sounds. The blue LED
goes out when blowing begins
(only for Interlock 7000).
or
With installed camera - optional:
Hold handset with the display in the direction of the camera.
Depending on the configuration, the blue LED within the camera
may flash when the handset is recognized.
Depending on the configuration, a breath sample may only be
possible if the blue LED is flashing and the handset is recognized.
Blow evenly into the mouthpiece as long as a continuous
tone sounds.
With anti-circumvention activated (blow/suck) – optional:
Blow evenly into the mouthpiece as long as a continuous signal
tone sounds, followed immediately (the signal tone ceases)
without pause by sucking hard until a short signal tone sounds.
If the breath sample is not provided in the correct way with the blow
and suck breathing technique, Repeat test is displayed.
Dräger Interlock 5000 / 7000
the
Confirm with the OK button.
The instrument will request a repeated breath sample.
If the breath sample flow is too hard or too soft, a corresponding
message is displayed.
Confirm with the OK button.
The instrument requests a repeated breath sample.
1
After an adequate breath sample, the test result is displayed with
Test passed or Test failed.
3.3.3

Test passed

The measured breath alcohol concentration is below the set limit value.
Test passed is displayed and the LED glows green (only for
Interlock 7000).
00233351.eps
The vehicle is cleared to start, Free Start Time is displayed and a
timer specifies how long the vehicle can be started.
After starting, the instrument is in stand-by mode and Drive Safely!
is displayed.
Attach handset to the holster again.
3.3.4

Test failed

The measured breath alcohol concentration is above the set limit value.
Test failed is displayed and the LED glows red (only for
Interlock 7000) followed by Next test in: with a timer displaying
the remaining disabled hours, minutes and seconds. The LED
remains lit until the instrument is ready to accept a further sample.
After an intermediate phase displayed via Preparing for test,
Ready for test. Please blow is displayed.
Provide further breath samples if necessary.
Use
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Interlock 7000

Table des Matières