7
Parameterisation 8200 vector/8200 motec
Menu structure
Main menu
No.
Display
11
LECOM/AIF
92
Submenus
No.
Display
Only active with standard devices from software version 2.2:
Change to the code level to display the levels at the terminals. The values
of the levels of the analog inputs and outputs are offset and gain.
10.13
Monit AIN1
10.14
Monit AIN2
10.15
Monit AOUT1
10.16
Monit AOUT2
10.17
Monit PTC
10.18
Monit DIGIN
10.19
Monit DIGOUT
11.1
LECOM setup
11.2
AIF setup
11.3
Status words
l
Description
Description
Level at analog input 1
0 ... 100 % (based on C0034)
Level at analog input 2
0 ... 100 % (based on C0034)
Level at analog output 1
0 ... 100 %
(basis for standard I/O: 10 V)
(basis for application I/O: C0424)
Level at analog output 2
0 ... 100 % (based on C0424)
Status of the PTC input
0 º open, 1 º closed
Status of the digital inputs and
the input for controller inhibit
X3/28
0 º LOW, 1 º HIGH
Status of the digital outputs and
status of the NO contact of the
relay outputs:
0 º LOW, 1 º HIGH
Configuration of operation with
communication modules
Serial interface
Process data
Display of status words