Lenze Global Drive Keypad E82 Instructions De Montage page 70

Module d'automatisme
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7
Parameterisation 8200 vector/8200 motec
Transmit parameter sets
Step
l
Copy individual parameter sets (PARx and FPAR1 if available) to the standard device:
– Standard device with
function module
application I/O,
INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
– Standard device with all
other function modules
or standard device
without function
module
7.
Start copying
8.
Change to the code level
9.
Enable controller
70
Key sequence
z
T V
V
A
V
B
U
l
Action
Copy PAR1 and FPAR1:
ð
Set "71" "Key−>FP1&PAR1"
Copy PAR2 and FPAR1:
ð
Set "72" "Key−>FP1&PAR2"
Copy PAR3 and FPAR1:
ð
Set "73" "Key−>FP1&PAR3"
Copy PAR4 and FPAR1:
ð
Set "74" "Key−>FP1&PAR4"
Copy PAR1:
ð
Set "11" "Keypad−>PAR1"
Copy PAR2:
ð
Set "12" "Keypad−>PAR2"
Copy PAR3:
ð
Set "13" "Keypad−>PAR3"
Copy PAR4:
ð
Set "14" "Keypad−>PAR4"
The selected parameter sets are copied to
the standard device or to the function
module.
"LOADING..." is displayed.
When "LOADING..." goes off, the copy
process is complete.
Display of the operating level
Display C0002 "Param managm"
The drive operates again
EDK82ZBC DE/EN/FR 4.0

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Global drive keypad e82 e82zbcGlobal drive keypad e82 e82zbb

Table des Matières