English
Use a forklift:
Features of the
- with suitable specifications in compliance with applicable standards
forklift
- NOT worn/damaged
stacker crane
- manual or electrical suitable for lifting the cabinet, with a nominal capacity
- with compliant and NON worn cables
• make sure there are no foreign objects within the handling area
Safe handling
• always place the lifting brackets in the indicated points
(how to pro-
• always introduce the brackets completely
ceed)
• balance the weight of the unit so as to ensure that the load remains balanced
DO NOT use transportation procedures other than those indicated

12. Storage

• the cabinets must be stored indoors, with a temperature ranging between
Remedy
• before storing the cabinets, check that the packing is intact and that it does
What to avoid

13. Installation, environmental conditions, first cleaning

WARNING!
Before carrying out any operation take all possible precautions to prevent injury to the
operator, use the individual Personal Protection Equipment provided
Installation is reserved to technicians trained and authorized by the body specified in the
contract (manufacturer/dealer/distributor)
- It is the responsibility of the customer to provide the installation area
- Changes to the setup described here must be authorized by ARNEG S.p.A.
The cabinet can be delivered packed as follows:
• with frame in wood fixed to the base and nylon casing blocked by straps (standard) (Fig.4).
• with a cardboard casing (on request) (Fig.5)
• with wooden crate (on request) (Fig.6)
36
greater than or equal to 1000 kg
(Fig.9)
WARNING! Heavy object. Crushing
Observe the indications regarding safe handling
Dragging. seizure/deformations/tearing
DO NOT drag/push the cabinet
DO NOT use the glass panels for attachment/support/grip
Observe the indications regarding safe handling
-25°C and +55°C and a humidity between 30% and 90%.
not display defect that may compromise preservation of the cabinets.
UV rays. Permanent deformation of plastic materials /damage of cabi-
net parts.
DO NOT store the cabinets in uncovered areas exposed to atmospheric
agents and to direct sunlight.