DIRECTIONS FOR USE - GVMAXV2-2/V2-2R
v03.20
12. MOUNTING OF GVOMAXV2 HOUSING
1. Screw the cover holding screw in your ejec-
tor holding plate. If there is no ejector holding
plate, use the nut and M4 washer.
2. Insert the end cap of the silencer in the
opening of the housing and put in place the
housing by screwing the knurled handle (M5
threaded) in the cover holding screw (M5 in-
ternal thread). Insert the M12 connectors in
the slits provided for that purpose.
3. End of the operation, housing on the vacuum
generator GVMAXV2-2/V2-2R.
www.coval.com
M4 screw for
cover holding
(use a 5 allen
key )
knurled handle
- 45 -
Use this mounting hole
housing
opening
silencer
end cap
cover holding screw
EN