DIRECTIONS FOR USE - GVMAXV2-2/V2-2R
v03.20

12. MOUNTING OF GVOMAXV2 HOUSING

1. Screw the cover holding screw in your ejec-
tor holding plate. If there is no ejector holding
plate, use the nut and M4 washer.
2. Insert the end cap of the silencer in the
opening of the housing and put in place the
housing by screwing the knurled handle (M5
threaded) in the cover holding screw (M5 in-
ternal thread). Insert the M12 connectors in
the slits provided for that purpose.
3. End of the operation, housing on the vacuum
generator GVMAXV2-2/V2-2R.