11.6 ZERO POINT SETTING
Use the + and – keys at the same time until
the 00 is shown, release the keys to end zero
setting.

11.7 PRESET VALUES

OUTPUT 1:
Switching output for vacuum regulation
H1 : -0.75
Output 1 = 1 when the switching point H1 is
reached. In case of vacuum loss below the
switching point L1, output 1 = 0
11.8 ERROR CODE INSTRUCTION
Error Name
Excess load
current
error
Residual pressure
error
Applied pressure
error
System error
www.coval.com
L1 : -0.65
Output 1 : NO
Error
Error instruction
code
OUT1
Er1
Excess load current of
125 mA
OUT2
Er2
During zero reset, ambient
Er3
pressure is over +/-3% F.S.
The applied pressure
HHH
exceeds the maximum
allowable pressure.
The applied pressure
exceeds the minimum
LLL
allowable pressure.
Er4
Internal data error
Internal system error
Er6
Internal data error
Er7
Internal system error
Er8
OUTPUT 2:
Switching output for «Gripped product» (to PLC)
H2 : -0.65
L2 : -0.55
Output 2 = 1 when the switching point H2 is
reached. In case of vacuum loss below the
switching point L2, output 1 = 0
Turn power off and check the cause
of overload current or lower the cur-
rent load under 125 mA, then restart
Change input pressure to ambient
pressure and perform zero reset again
(see §11.6 Zero Point setting).
Adjust the pressure within applied
pressure range.
Turn power off, and then restart.
If error condition remains, please
return to factory inspection.
- 44 -