Télécharger Imprimer la page

EINHELL TE-AC 400/50/10 V Instructions D'origine page 20

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
vessel. If you discover any damage, please con-
tact the customer service workshop.
Notice!
The condensation water from the pressure
vessel will contain residual oil. Dispose of the
condensation water in an environmentally
compatible manner at the appropriate collec-
tion point.
8.3 Safety valve (10)
The safety valve has been set for the highest per-
mitted pressure of the pressure vessel. It is prohi-
bited to adjust the safety valve or remove its seal.
Actuate the safety valve from time to time to en-
sure that it works when required. Pull the ring with
suffi cient force until you can hear the compressed
air being released. Then release the ring again.
8.4 Check the oil level at regular intervals
Place the compressor on a level and straight
surface. The oil level must be between the two
marks MAX and MIN on the oil oil level window
(Fig. 11).
Changing the oil: Recommended hydraulic oil:
SAE 15W/40 or an alternative of the same quality.
It should be refi lled for the fi rst time after 100
hours of operation. Thereafter the oil should be
drained and refi lled after every 500 hours in ser-
vice.
8.5 Changing the oil
Switch off the engine and pull the mains plug out
of the socket. After releasing any air pressure you
can unscrew the oil drainage screw (15) from the
compressor pump. To prevent the oil from running
out in an uncontrolled manner, hold a small metal
chute under the opening and collect the oil in a
vessel. If the oil does not drain out completely, we
recommend tilting the compressor slightly.
Dispose of the old oil at a drop-off point for
old oil.
When the oil has drained out, re-fi t the oil draina-
ge screw (15). Fill new oil through the oil fi ller ope-
ning (17) until it comes up to the required level.
Then replace the oil sealing plug (14).
8.6 Cleaning the intake fi lter (1)
The intake fi lter prevents dust and dirt being
drawn in. It is essential to clean this fi lter after at
least every 300 hours in operation.
A clogged intake fi lter will decrease the
compressor's performance dramatically. Undo the
Anl_TE_AC_400_50_10_V_SPK9.indb 20
Anl_TE_AC_400_50_10_V_SPK9.indb 20
GB
screw on the air fi lter so that the halves of the air
fi lter housing can be opened. Use compressed
air at low pressure (approx. 3 bar) to blow out all
the parts of the fi lter and then assemble the fi lter
in reverse order. When cleaning, take adequate
precautions against dust (e.g. use a suitable face
mask).
8.7 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Warning!
Store the compressor only in a dry location
which is not accessible to unauthorized per-
sons. Always store upright, never tilted!
Store the equipment and accessories in a dark
and dry place at above freezing temperature. The
ideal storage temperature is between 5 and 30
°C. Store the electric tool in its original packaging.
8.8 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
9. Disposal and recycling
The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council offi ces.
- 20 -
26.01.2018 06:29:16
26.01.2018 06:29:16

Publicité

loading

Ce manuel est également adapté pour:

40.104.72