Télécharger Imprimer la page

EINHELL TE-AC 400/50/10 V Instructions D'origine page 19

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
6.2 Fitting the supporting feet (4)
Fit the supplied supporting feet (4) as shown in
Fig. 6.
6.3 Fitting the transport handle (9)
Screw the transport handle (9) to the compressor
as shown in Figures 7 to 8.
6.4 Replacing the oil sealing plug (14)
Remove the transportation cover from the oil fi ller
opening with a screwdriver and insert the sup-
plied oil sealing plug (14) into the oil fi ller opening
(Fig. 9).
6.5 Fitting the air fi lter (1)
Use a screwdriver to remove the transportation
cover from the air fi lter connection.
Screw in the supplied air fi lter (Fig. 10).
6.6 Power supply
The motor is fitted with an overload switch
(Fig. 3/Item 16). If the compressor overloads,
the overload switch switches off the equip-
ment automatically to protect the compressor
from overheating. If the overload switch trig-
gers, switch off the compressor using the ON/
OFF switch (8) and wait until the compressor
cools down. Then press the overload switch
(16) and restart the compressor.
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
In the case of low temperatures below +5°C,
motor start-up is jeopardized as a result of
stiffness.
6.7 On/Off switch (8)
To switch on the compressor, pull out the knob
(8).
To switch off the compressor, press the knob (8)
back in. (Figure 2)
6.8 Adjusting the pressure: (Fig. 1,2)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be taken from the quick-
lock coupling (5).
6.9 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 7,5 bar
Switch-off pressure 10 bar
Anl_TE_AC_400_50_10_V_SPK9.indb 19
Anl_TE_AC_400_50_10_V_SPK9.indb 19
GB
7. Replacing the power cable
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Warning!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Warning!
Wait until the compressor has completely
cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
Warning!
After use, always switch off the equipment
immediately and pull out the power plug.
8.1 Cleaning
Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at
low pressure.
We recommend that you clean the appliance
immediately after you use it.
Clean the appliance regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be
aggressive to the plastic parts in the appli-
ance. Ensure that no water can get into the
interior of the appliance.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensation water (Fig. 1)
Important. To ensure a long service life of the
pressure vessel (2), drain off the condensed wa-
ter by opening the drain valve (11) each time after
using. Check the pressure vessel for signs of rust
and damage each time before using. Do not use
the compressor with a damaged or rusty pressure
- 19 -
26.01.2018 06:29:16
26.01.2018 06:29:16

Publicité

loading

Ce manuel est également adapté pour:

40.104.72