5.2 Installation air-cooled units (version L)

Fig. 5.2.a: Back view L-model
To ensure safe operation, in air-cooled units a minimum distance to walls on all sides and at the top has to be
adhered to (see Fig. 5.2.a).
The warm air generated in air-cooled units must be able to escape upwards without obstruction, because
otherwise there is a risk of an air short circuit.
CAUTION: If an air-cooled ice cube maker is installed in a small, enclosed room, it is important to ensure
adequate air circulation (fresh air supply).
5.2.1 Please connect the enclosed inlet hose (DN 8; ¾"–screwing) with the water inlet (2) and with the water
tab (cold water-/ fresh water inlet).
5.2.2 Please connect the enclosed outlet hose (DN 20) with the residual water outlet (3), then run the water
drain tube to the waste water system. Ensure that the tube has a continuous gradient and no bends. Without
adequate gradient of the drain tube, the storage container may overflow and cause water damage.
CAUTION: For hygienic reasons, the outlet hose must not be connected directly to the waste water
system (see Fig. 5.2.b).
5.2.3 Insert the power plug (1) into the socket.