Trough is not filled with water
Storage container contains water Drain tube of the storage container
Water consumption in water-
cooled machines is too high

8. Disposal

8.1 Disposal instructions

If the machine would be put out of service, please follow the instructions below for disposal:
The refrigerant circuit of the ice cube maker contains HFC and lubricants that are harmful to water!
The machine must therefore be disposed of properly according to the relevant environmental protection
regulations. Should you have no options for proper disposal, please contact your specialist dealer or
WESSAMAT directly.
1. Water inlet valve clogged or
soiled
2. Electrical fault in water inlet
valve
3. Water level sensor affected by a
'moisture bridge'
4. Fault in water sensor electronics
is kinked or clogged
Flow through cooling water
controller is too high
45
1. Clean pre-screen
2. Check input voltage, replace water
inlet valve if necessary
3. Dry the water level sensor
4. Replace water sensor electronics
Ensure free water drainage
Readjust or replace cooling water
controller