5.3 Installation air-cooled, built-in units (version LE)

E
N
G
L
I
S
C
H
E
N
G
L
I
S
H
A
N
G
Air-cooled, built-in type ice cube makers can be installed without taking into account the minimum distances.
L
However there should be distance to the wall from the back side of the machine in order to have enough space
A
I
for the connection tubes (see Fig. 5.3.a).
S
Before installation please hook in the enclosed lateral air-inlet grille (see Fig. 5.3.a) at the right machine side
into the designated holes from above downwards.
CAUTION: When the device is pushed back in, the water drain tube may become bent or kinked, thus
preventing draining of the water. Please keep an eye on the tube during re-assembly.
5.3.1 Please connect the enclosed inlet hose (DN 8; ¾"–screwing) with the water inlet (2) and with the water
tab (cold water-/ fresh water inlet).
5.3.2 Please connect the enclosed outlet hose (DN 20) with the residual water outlet (3), then run the water
drain tube to the waste water system. Ensure that the tube has a continuous gradient and no bends. Without
adequate gradient of the drain tube, the storage container may overflow and cause water damage.
CAUTION: For hygienic reasons, the outlet hose must not be connected directly to the waste water
system (see Fig. 5.3.b).
5.3.3 Insert the power plug (1) into the socket.
Fig. 5.3.a: Back view LE-model
36
Fig. 5.3.b: Outlet proposition