Technical Data And Operating Conditions M 400 - Wessamat Micro Cube M 120 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating instructions

4.6 Technical data and operating conditions M 400

General data
Cooling
Model-version
Dimensions ice cube maker
H x B x T (mm)
Weight (kg)
Model-version
Dimensions ice cube maker with storage bin
(H= without feet); H x B x T (mm)
Adjustable feet from – till (mm)
Weight (kg)
Model-version
Dimensions ice cube maker with intermediate
storage and ice transport cart
(H= incl. feet); H x B x T (mm)
Weight (kg)
Refrigerant R404a (g)
Refrigeration performance
Evaporating temperature
Production data (under ideal conditions)
Production (kg per day)
Storage in storage bin (kg)
Storage in intermediate storage (kg)
Storage in transport cart (kg)
Water consumption for ice production
(litres per kg)
Water consumption for cooling
(litres per kg)
Power supply
Voltage
Power consumption
Fuse (provided by customer)
Length of connection cable
Water supply
Pressure
Temperature (ideal/ permitted)
Water hardness
Conductance
Water inlet
Device connection -Ø
Hose -Ø / - Length
Water outlet
Device connection -Ø
Hose -Ø / - Length
Cooling water-forward flow
Device connection -Ø
Hose -Ø / - Length
Cooling water-return flow
Device connection -Ø
Hose -Ø / - Length
Environmental conditions
Temperature (ideal/ permitted)
Installation position
Installation height
BA-MicroCube-1213-0
*) in case this maximum value will be exceeded, accordingly purified water has to be used!
15-20 °C/ 10-30 °C
the installation surface must be suitable for the weight of the machine
air
LP
540 x 800 x 605
112
L
1995 x 805 x 605
150-170
185
LF
2445 x 800 x 1220
284
1500
-
-
-
400 V ~ / 50 Hz
1,70 kW
about 2,0 m
2 to 6 bar (28,6 to 85,7psi)
10–15 °C/ 2–25 °C
max. 10 °dH (12,5 °eH) *)
max. 300 µS/cm *)
¾" - male thread
DN 8 (incl. 2x ¾" – female thread) / about 1,5 m
20 mm
DN 20 / about 1,4 m
-
¾" - male thread
-
DN 8 (incl. 2x ¾" – female
thread) / about 1,5 m
-
¾" - male thread
-
DN 10 (incl. ¾" – female
thread) / about 1,4 m
firm surface, good ventilation,
at least 10 cm above outlet pipe
water
WP
98
W
171
WF
270
400
-
-
400
250
318
109
1,0
4,8
1,50 kW
0,55 kW
≥ 16 A
15-20 °C/ 10-45 °C
English
central
ZP
63
Z
136
ZF
235
-
2,6 kW
-20 °C
-
-
-
-
-
7

Publicité

Table des Matières
loading

Table des Matières