Technical Data And Operating Conditions M 120 - Wessamat Micro Cube M 120 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating instructions

4.4 Technical data and operating conditions M 120

General data
Cooling
Model-version
Dimensions ice cube maker
H x B x T (mm)
Weight (kg)
Model-version
Dimensions ice cube maker with storage bin
(H= without feet); H x B x T (mm)
Adjustable feet from – till (mm)
Weight (kg)
Model-version
Dimensions ice cube maker with intermediate
storage and ice transport cart
(H= incl. feet); H x B x T (mm)
Weight (kg)
Refrigerant R404a (g)
Refrigeration performance
Evaporating temperature
Production data (under ideal conditions)
Production (kg per day)
Storage in storage bin (kg)
Storage in intermediate storage (kg)
Storage in transport cart (kg)
Water consumption for ice production
(litres per kg)
Water consumption for cooling
(litres per kg)
Power supply
Voltage
Power consumption
Fuse (provided by customer)
Length of connection cable
Water supply
Pressure
Temperature (ideal/ permitted)
Water hardness
Conductance
Water inlet
Device connection -Ø
Hose -Ø / -Length
Water outlet
Device connection -Ø
Hose -Ø / -Length
Cooling water-forward flow
Device connection - Ø
Hose -Ø / -Length
Cooling water-return flow
Device connection - Ø
Hose -Ø / -Length
Environmental conditions
Temperature (ideal/ permitted)
Installation position
Installation height
BA-MicroCube-1213-0
0,90 kW
*) in case this maximum value will be exceeded, accordingly purified water has to be used!
15-20 °C/ 10-30 °C
the installation surface must be suitable for the weight of the machine
air
water
LP
540 x 600 x 605
77
L
1540 x 605 x 605
150-170
123
LF
1735 x 790 x 1020 (1150 incl. cart)
175
800
-
-
-
400 V ~ / 50 Hz
0,90 kW
≥ 16 A
about 2,0 m
2 to 6 bar (28,6 to 85,7psi)
10–15 °C/ 2–25 °C
max. 10 °dH (12,5 °eH) *)
max. 300 µS/cm *)
¾" –male thread
DN 8 (incl. 2x ¾" –female thread) / about 1,5 m
20 mm
DN 20 / about 1,4 m
-
¾" –male thread
-
DN 8 (incl. 2x ¾" –female
thread) / about 1,5 m
-
¾" –male thread
-
DN 10 (incl. ¾" –female
thread) / about 1,4 m
firm surface, good ventilation,
at least 10 cm above outlet pipe
central
WP
75
W
121
WF
173
270
-
0,8 kW
-
-15 °C
120
100
45
109
1,0
5,3
0,30 kW
15-20 °C/ 10-45 °C
English
ZP
58
Z
104
ZF
156
-
-
-
-
-
-
5

Publicité

Table des Matières
loading

Table des Matières