4.4 Technical data and operating conditions

Model
General data
Machine dimensions
without front metal sheet
H x W x D (mm)
Machine dimensions
with front metal sheet
H x W x D (mm)
Weight (kg)
Cooling
Production data
Production (kg per day)
Storage (kg)
Water consumption of ice making (litres
E
per kg)
N
Water consumption of cooling system
G
(litres per kg)
L
I
Power supply
S
Voltage
C
Power consumption
H
Fuse (provided by customer)
Length of connection cable
E
N
G
Water supply
L
Pressure
I
Temperature (ideal/ permitted)
S
Water hardness
H
Water inlet
device connection -Ø
A
hose –Ø / -length
N
G
Water outlet
L
device connection -Ø
A
hose –Ø / -length
I
Bursting pressure - water cycle
S
Cooling cycle
Bursting limit
Environmental conditions
Temperature (ideal/ permitted)
Installation position
Installation height
The installation surface must be suitable for the weight of the machine.
*) If the water hardness exceeds the maximum value, the use of a softener is recommended.
W20 W
455 x 555 x 441
458 x 595 x 460
47
water
about 20
about 5
about 3
about 15
230 V ~ / 50 Hz
0,30 kW
≥ 10 A
about 2,0 m
2 to 6 bar (28,6 to 85,7psi)
10–15 °C/ 2–25 °C
max. 15 °dH (19 °e) *)
¾ "
OD:10 mm – ID:7 mm / about 2,0 m
20 mm
DN 20 / about 0,215 m
15 bar
70 bar
15-20 °C/ 10-45 °C
firm surface, good ventilation
at least 10 cm above outlet pipe