Technical Data - Scheppach MBS1100 Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
g) If dust vacuums or catching systems can be in-
stalled on the tool, make sure that these are cor-
rectly connected and assembled. The use of a
dust exhaust unit can reduce hazards caused by
dust.
4 Use and treatment of the power tool
a) Do not overtax the tool. Use the appropriate tool
for the work that is to be done. With the correct
power tool, you can work better and more safely.
b) Do not use a power tool where the switch is de-
fective. A power tool that cannot be turned on and
off is dangerous and must be repaired.
c) Disconnect the plug from the wall outlet before
you make adjustments to the tool, change parts
or put the tool away. This precaution prevents
inadvertent start-ups of the tool.
d) Store power tools that are not in use out of reach
of children. Do not let anyone use the tool who
does not have experience with it, or who has not
read these instructions. Power tools can be dan-
gerous when they are used by inexperienced
people.
e) Take good care of your power tools. Make sure
that movable parts function properly and do not
jam, see that parts which influence the use of
the machine are not broken or damaged. Repair
damaged parts before operating the tool. Many
accidents are caused by poorly maintained power
tools.
f) Keep cutting edges sharp and clean. Properly
maintained cutting tools with sharp cutting edges
jam less often and are easier to control.
g) Use power tools, accessories, and equipment ac-
cording to these instructions. Taking into account
the working conditions and the work being per-
formed.
The use of power tools other than those
intended for the tool itself can lead to dangerous
situations.
5 Service
a) Only let qualified service personnel repair your
tool and always use original replacement parts.
This guarantees that the power tool remains safe
to use.
Warning! This electric tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain
conditions. In order to prevent the risk of serious or
deadly injuries, we recommend that persons with
medical implants consult with their physician and the
manufacturer of the medical implant prior to operat-
ing the electric tool.
Additional safety instructions - portable band
saws
When performing work during which the cutting de-
vice could come into contact with concealed power
lines, hold the electrical tool by the insulated han-
dle surfaces. Contact between the cutting tool and
22
GB
a live power line can also electrify metal device
parts and lead to an electric shock.
Keep your hands away from the sawing area and
saw blade.
Before use, always ensure that the portable band
saw is clean.
Stop operation immediately, if you notice anything
unusual.
Prior to using the tool, always make sure that all
components are properly and safely fitted.
Always proceed with caution when fitting or remov-
ing the band saw blade.
Always keep your hands away from the cutting
path of the band saw blade.
Before sawing, always wait until the motor has
reached full speed.
Always keep the handles dry, clean and free of oil
and grease. Hold the tool firmly during work.
Always remain alert, in particular when performing
repetitive, monotonous tasks. Always make sure
your hands are in the correct position in relation
to the saw blade.
Never remove the workpiece stop.
Maintain a distance from end pieces, which fall
down after sawing. They may be hot, sharp and/or
heavy. They could cause serious injuries.
Air intakes often cover moving parts and should
be kept clear. Loose-fitting clothing, jewellery and
long hair may become caught in the moving parts.

6. Technical data

Motor
Power
Protection class
Saw band
Saw band speed
Cutting width 90°
Cutting width 45°
Swivel range
Weight Metal band saw
Weight
The total noise values determined in accordance
with EN 60745.
sound pressure level L
pA
uncertainty K
pA
sound power level L
WA
uncertainty K
WA
Wear hearing protection.
The effects of noise can cause a loss of hearing.
Total vibration values (vector sum - three directions)
determined in accordance with EN 60745.
220 - 240 V ~, 50
Hz
1100 W
II
1140x12,7x0,65
0,7 - 2,4 m/s
127x127 mm
127x40 mm
0°-45°
6,6 kg
13,6 kg
89 dB(A)
3 dB
100 dB(A)
3 dB