MAINTENANCE AND TEChNICAl SUPPORT
6) Undo the screws on the oil tank. Remove the oil tank.
7) Clean each part of the tank carefully with a cloth soaked in the same type of oil used in the pump.
8) Clean the seat of the gasket carefully and put in a new gasket if the old one is worn or damaged.
9) Refasten the tank or oil cover.
10) Place the new filter in seat:
4 m³/h PUMP: turn clockwise.
8-12-18-25 m³/h PUMP: position the filter with o-ring and use the pliers to screw on the new cap provided with the filter.
11) Refasten the drain cap on the base of the pump.
12) Refill with oil and then close the machine following steps 13 to 19 in section 11.7.
76
Rev. 05 - 04/2018 - Cod. 1500458 - Instruction manual for vacuum chamber packaging machines with digital control panel "Serie Bright"
8 m