Commissioning And Operation - Aventics PE2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
AVENTICS | PE2 | R412006964–BAL–001–AE | English
6

Commissioning and Operation

Dangerous system operating states from incorrect settings or if the maximum/minimum
operating voltage is exceeded!
Danger of injury and system damage from uncontrolled system operating states.
O
Do not make any improper changes to the PE2 during operation. Note that the previous
settings become immediately effective if the
O
Immediately exchange defective pressure switches.
O
Do not disconnect the PE2 pressure switch from the voltage source during operation!
Damage by sharp objects!
The device may be damaged.
O
Never operate the device with tools or sharp objects.
Before commissioning the system, the following steps
must have been carried out and completed:
W
You have fully assembled and connected the PE2.
W
You have carried out the presettings and configuration.
You can now pressurize the system part to which the PE2 is connected.
Switching on the device
After connecting to the power supply, the device displays the manufacturer name for 5 seconds.
The measuring and switching functions are operational in the display mode.
In the case of an electrical start-up, the device may already show a value in a
pressure-free state (physical effect). During commissioning, perform a zero point
offset in the EF extended program function with the function ZERO.
Selecting the programming mode
The PE2 is in display mode:
O
Press the
button.
The PE2 is now in the programming mode. The measuring and switching functions continue.
If you do not make an entry for more than 10 s, the device automatically switches back to the
display mode.
Selecting menu items or parameters
The PE2 is in the programming mode:
The device displays menu items and selectable parameters in the display area 3 (Fig.
addition, a text describing the menu items is displayed. The language of the descriptive text can
be set in the LANG menu item in the EF extended programming functions.
O
Use the
and
buttons to select the menu item or parameter to be set.
To confirm the menu item or parameter:
O
Press the
button.
The menu item will be implemented or you can set the parameter values.
Setting parameter values
The PE2 is in the programming mode:
The device displays parameter values in the display area 3 (Fig.
O
Use the
and
buttons to select the parameter value to be set.
To confirm the parameter value:
O
Press the
button.
The setting becomes active, although the device is still in the programming mode.
Selecting the switching and resetting points or the extended
programming functions
The PE2 is in the programming mode:
1. Press
or
repeatedly, until the desired switching point (SP1, SP2), the resetting point
(RP1, RP2) or the display for the extended programming functions (EF) appears on the
display.
The following displays appear in sequence:
1)
Display
Explanation
SP1/FH1
Switching point 1 or upper window limit 1
Value range: ≥ 0.5% FS to 100% FS
Factory setting: measurement range -1 to +1 bar: +0.5 bar;
measurement range 0 to 16 bar: +10 bar
RP1/FL1
Resetting point 1 or lower window limit 1
Value range: 0% FS to SP-0.5% FS (or +0.5% FS, if SP < 0)
Factory setting: measurement range -1 to +1 bar: -0.5 bar;
measurement range 0 to 16 bar: +6 bar
SP2/FH2
Switching point 2 or upper window limit 2 (if second switched output is
present)
Value range: ≥ 0.5% FS to 100% FS
Factory setting: measurement range -1 to +1 bar: +0.5 bar;
measurement range 0 to 16 bar: +10 bar
CAUTION
button is pressed!
NOTICE
6
).
1)
Display
Explanation
RP2/FL2
Resetting point 2 or lower window limit 2 (if second switched output is
present)
Value range: 0% FS to SP -0.5% FS (or +0.5% FS, if SP < 0)
Factory setting: measurement range -1 to +1 bar: -0.5 bar;
measurement range 0 to 16 bar: +6 bar
EF
Extended programming functions (see "Selecting the extended
programming functions")
1) In the window mode, the switching and resetting points SPx, RPx are called FHx and FLx.
2. Press
to confirm the selection.
You can now enter the parameter values for the switching points.
Selecting the extended programming functions
The PE2 is in the programming mode:
1. Press
or
repeatedly until EF appears in the display.
2. Press
to go to the extended programming functions.
3. Press
or
repeatedly until the desired parameter appears in the display.
Display
Explanation
RES
Reset the set parameters to factory settings
Value range: YES, NO (when YES, device restarts)
Factory setting: NO
DS1
Switching delay 1
Value range: OFF, 0.2–50 s
Factory setting: OFF
DR1
Reset delay 1
Value range: OFF, 0.2–50 s
Factory setting: OFF
DS2
Switching delay 2
(if second switched output is present)
Value range: OFF, 0.2–50 s
Factory setting: OFF
DR2
Reset delay 2
(if second switched output is present)
Value range: OFF, 0.2–50 s
Factory setting: OFF
OU1
Switching function, switched output 1
6
). In
W
Hysteresis function, normally open (HNO)
W
Hysteresis function, normally closed (HNC)
W
Window function, normally open (FNO)
W
Window function, normally closed (FNC)
Value range: HNO, HNC, FNO, FNC
Factory setting: HNO
OU2
Switching function, switched output 2
Iff 2xPNP:
W
Hysteresis function, normally open (HNO)
W
Hysteresis function, normally closed (HNC)
W
Window function, normally open (FNO)
W
Window function, normally closed (FNC)
Value range: HNO, HNC, FNO, FNC
Factory setting: HNO
OUA
If an analog signal is present (4–20 mA), inversion is possible (IINV):
W
Output signal 4-20 mA (I)
W
Inverted output signal 20-4 mA (IINV)
Value range: I, IINV,
Factory setting: I
UNI
Setting the pressure unit in the display
Value range: bar, mbar, Mpa, kPa, psi, %
Factory setting: bar
DISP
Automatic display switch-off
Value range: OFF, 1–60 min
Factory setting: OFF
DISR
Electronically invert each display field
Value range: YES, NO
Factory setting: NO
ZERO
Zero point offset correction,
max. ±50 mbar at -1 to +1 bar or max. ±160 mbar at 0 to 16 bar
Value range: –
Factory setting: –
PASS
Set the password for menu lock
Value range: NO, 0000-9999
Factory setting: NO
LANG
Change language for additional plain text menu
Value range: DE, EN, ES, FR, IT, OFF
Factory setting: DE
6

Publicité

Table des Matières
loading

Table des Matières