Actuator Size 100, 125 (Ø In Mm) - Burkert 2000 Instructions De Montage

Masquer les pouces Voir aussi pour 2000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Type 2000, 2002, 2012
2030, 2031, 2032, 2033
Maximumstrokelimitation
7.2 Actuator size 100, 125 (Ø in mm)
Loctite 274
Fig. 4:
Actuator size 100, 125 (Ø in mm),
maximum stroke limitation without position feedback
7.2.1 Work to be carried out before
installation
Interrupt supplies of control air and medium.
Empty valve body.
Unscrew transparent cap from actuator cover ⑥
(Follow safety instructions Chapter "7", page 10!).
Screw out position indicator with Allen key (size 8).
NOTE!
Damage to the actuators due to incorrect tool.
• Screw in or unscrew actuator cover only with the special
wrench offered in Chapter "12 Assembly accessories".
Parts required
1 Threaded nipple
2 Setscrew M12 x 1.5
3 Nut M12 x 1.5
4 Nut
5 O-ring
6 Actuator cover
7 Sleeve
8 Disk
Screw off actuator cover ⑥ with special wrench, counterbracing
at the sleeve.
7.2.2 Installation and start-up
NOTE!
Functional failure or impairment due to damaged o-ring ⑤.
• Insert o-ring ⑤ carefully.
• Do not use sharp objects.
Insert threaded nipple ① into actuator cover ⑥.
Place disk ⑧ inside the actuator cover ⑥.
Fix actuator ⑥ cover with nut ④ on the threaded nipple ① .
• Use flats on tube for wrench (size 24)
• Max. tightening torque: 20 Nm
Secure nut ④ with Loctite 274.
Assemble actuator cover ⑥ with special wrench.
• Max. tightening torque: Actuator size Ø 100 mm = 45 Nm
Set max. stroke by adjusting the setscrew ②.
Secure setscrew ② with nut ③.
Test valve for function and leaktightness.
english
Actuator size Ø 125 mm = 60 Nm
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

200220122030203120322033

Table des Matières