Type 2000, 2002, 2012
2030, 2031, 2032, 2033
Maximumstrokelimitation
7.2 Actuator size 100, 125 (Ø in mm)
Loctite 274
Fig. 4:
Actuator size 100, 125 (Ø in mm),
maximum stroke limitation without position feedback
7.2.1 Work to be carried out before
installation
→
Interrupt supplies of control air and medium.
→
Empty valve body.
→
Unscrew transparent cap from actuator cover ⑥
(Follow safety instructions Chapter "7", page 10!).
→
Screw out position indicator with Allen key (size 8).
NOTE!
Damage to the actuators due to incorrect tool.
• Screw in or unscrew actuator cover only with the special
wrench offered in Chapter "12 Assembly accessories".
Parts required
1 Threaded nipple
2 Setscrew M12 x 1.5
3 Nut M12 x 1.5
4 Nut
5 O-ring
6 Actuator cover
7 Sleeve
8 Disk
→
Screw off actuator cover ⑥ with special wrench, counterbracing
at the sleeve.
7.2.2 Installation and start-up
NOTE!
Functional failure or impairment due to damaged o-ring ⑤.
• Insert o-ring ⑤ carefully.
• Do not use sharp objects.
→
Insert threaded nipple ① into actuator cover ⑥.
→
Place disk ⑧ inside the actuator cover ⑥.
→
Fix actuator ⑥ cover with nut ④ on the threaded nipple ① .
• Use flats on tube for wrench (size 24)
• Max. tightening torque: 20 Nm
→
Secure nut ④ with Loctite 274.
→
Assemble actuator cover ⑥ with special wrench.
• Max. tightening torque: Actuator size Ø 100 mm = 45 Nm
→
Set max. stroke by adjusting the setscrew ②.
→
Secure setscrew ② with nut ③.
→
Test valve for function and leaktightness.
english
Actuator size Ø 125 mm = 60 Nm
11