Sony VPL-PX40 Mode D'emploi page 40

Masquer les pouces Voir aussi pour VPL-PX40:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3
Remove the air filter.
4
Wash the air filter with a mild
detergent solution and dry it in a
shaded place.
5
The openings on the bottom of the
projector (A~D) should also be
cleaned with a vacuum cleaner.
C
6
Insert the air filter into the four tabs of
the air filter cover, and then attach the
air filter cover to the projector.
40
GB
Maintenance
• If you neglect to clean the air filter, dust
Small filter
holes
Large
filter holes
• If the dust cannot be removed from the air
• Be sure to attach the air filter cover firmly;
• The air filter has a face and a reverse side.
D
A
B
Notes
may accumulate, clogging it. As a result,
the temperature may rise inside the unit,
leading to a possible malfunction or fire.
filter, replace the air filter with the supplied
new one.
the power will not be turned on if it is not
closed securely.
The side of the filter with the narrower
openings should face the outside.