Programming The Increase Of The Melting Temperature; Program Tables - DeguDent Prestomat Compact Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5.2 Programming the melting temperature increase
Step
Key
1
Progr.
2
+ °C
3
E
4
or Progr.
The adjusted value of the melting temperature increase is used by all programs.

5.3 Program tables

Melting temperature increase (upon delivery + 10 °C)
Table 1
Program
number
(alloy)
0
Degunorm
®
1
Degunorm
®
supra
2
Degunorm
®
pur
3
BiOcclus
®
HT
4
Degudent
®
U
5
Degudent
®
H
6
Degulor
®
M
7
Deva
®
4
8
Stabilor
®
NF IV
9
Degupal
®
G
32
Function
Activates the programming mode (access to all programs).
When pressing this key the lamp is lit and the stored
temperature is shown in the display.
Select the desired value by pressing
Stores the data, ends the programming mode and returns to the old position.
Starting
Melting
°C
°C
0850
1150
0850
1240
0850
1200
1000
1280
1100
1400
1100
1400
0900
1200
1150
1450
0950
1180
1100
1450
or
.
Time of
Pressure
further
delay
heating
15 s
45 s
45 s
45 s
2 min 45 s
1 min 45 s
15 s
2 min 45 s
15 s
2 min 45 s
Cooling
0.1 s
1 min
0.1 s
1 min
0.1 s
1 min
0.2 s
1 min
0.2 s
1 min
0.2 s
1 min
0.1 s
1 min
0.2 s
1 min
0.1 s
1 min
0.2 s
1 min 30 s

Publicité