Technical Data; Connection Data - Lenze APPLICATION−I/O PT E82ZAFAC010 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6

Technical data

Connection data

6
Technical data
Connection data
X3.1/
1U/2U
1I/2I
X3.2/
62
63
9
X3.3/
A1
A2
A4
20
28
1)
E1
1)
E2
E3
E4
E5
E6
1)
optionally frequency input 0 ... 102.4 kHz (one−track or two−track), configuration via C0425
40
Temperature error (0 ... +60 °C) for level (based on actual value):
l
0 ... +5 V:
l
0 ... +10 V:
l
−10 ... +10 V:
l
0/+4 ... +20 mA:
±
Linearity distortion:
A/D converter:
Resolution: 10 bits,
Error (based on the final value): 1 digit
Input resistance: voltage signal: > 50 k
Resolution: 10 bits
Linearity distortion (based on the actual value):
Temperature error (0 ... +60 °C): 0.6 %
Load capacity (0 ... +10 V): I
Load resistance (0/+4 ... +20 mA):
Load capacity: I
= 5 mA
max
Load capacity:
l
I
= 10 mA, with internal supply
max
l
I
= 50 mA, with external supply
max
Load capacity: I
= 8 mA
max
f = 50 Hz ...10 kHz
S
Load capacity:
I
= 60 mA
max
Input resistance: 3.2kW
1 = HIGH (+12 ... +30 V), PLC level, HTL
0 = LOW (0 ... +3 V), PLC level, HTL
1 %
0.6 %
0.6 %
0.6 %
0.5 %
º
0.1 %
W
, current signal: 250
= 2 mA
max
£
W
500
l
W
±
0.5 %
EDK82ZAFAC−010 DE/EN/FR 6.0

Publicité

Table des Matières
loading

Table des Matières