Commissioning Using Lenze Settings - Lenze APPLICATION−I/O PT E82ZAFAC010 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Commissioning using Lenze settings

Step
Procedure
1.
Switch on the mains
voltage.
2.
Control digital inputs.
3.
Select setpoint
4.
Enable controller via
terminal.
5.
The drive should be running now.
)
Note!
The controller is only ready for operation if a HIGH signal is applied to
ƒ
X3.3/28 (controller enable via terminal).
– Please observe that the controller can be inhibited through various
sources. All sources act like a series connection of switches.
– If the drive does not start although the controller has been enabled via
X3.3/28, check whether the controller has been inhibited through a
different source. Another source could be the s−key of the keypad.
EDK82ZAFAC−010 DE/EN/FR 6.0
Commissioning using Lenze settings
Comments
After approx. 1 second, the controller is ready for operation.
Controller inhibit is active.
Controller reaction
The green LED is blinking.
dc
Keypad:
(if attached)
Lenze setting
l
CW rotation:
– E1, E2, E3, E4: LOW
l
CCW rotation:
– E1, E2, E3: LOW
– E4: HIGH
Individual setting
Adapt digital inputs under C0007 or C0410.
The digital inputs must be controlled so that the drive can
start via terminal after controller enable.
Lenze setting
Setpoint: 0 ... +10 V
Individual setting
l
Depending on jumper position at module
– Apply master current to X3.1/1I or X3.1/2I or
– apply master voltage to X3.1/1U or X3.1/2U
l
Check C0034
Lenze setting
X3.3/28 = HIGH (+12 V ... +30 V)
Controller reaction
The green LED is on.
c
Keypad:
Off
l