Dual Filtration System

The turbine has two different air filters— one for atomizing air
and one for cooling air. The atomizing air filter (1) is a two-stage,
fine mesh filter designed to trap particles that may damage your
finish. The atomizing air is discharged through the nozzle of the
spray gun where it atomizes the coating material (2). The cooling
air filter (3) is a coarse mesh filter designed to allow the proper
amount of air flow through the turbine for cooling purposes.
Cooling air is exhausted through the cooling air discharge on the
front of the turbine (4).
3
Filter Warning System
The filter warning system on your turbine consists of a red filter
warning light on the front control panel and an air flow switch
inside the turbine. When the air flow switch does not detect the
appropriate amount of air flowing through the turbine, the filter
warning light will come on to indicate that it is time to clean or
change the filters.
i
The filter warning system does not shut down
the turbine.
Clean filters regularly. Clogged filters can cause
excessive heat and possibly damage the turbine.
Attention
2
1
4
GB

Maintenance

Use the following procedures to keep your HVLP spray system
running properly.
Cleaning/Replacing the Filters
1. Remove each filter by grabbing them and pulling them
straight out of the filter cans on the turbine. This will not
damage the filters.
2. Clean the filters. Either tap the filters to knock out the
contaminants or use pressurized air to blow out the
contaminants. For material that is not blown or knocked
loose easily, soak the filters in soapy water or minearal
spirits. Allow the filters to dry completely before placing
them back in the turbine.
Do not use highly flammable solvents, such as
lacquer thinner, to clean the filters.
Attention
3. Insert each filter back into its corresponding filter can.
The two-stage, atomizing air filter (Fig. 3, item 1)
i
must be placed in the filter can labeled "2-Stage
Filter" with the green side facing the turbine.
After several cleanings, it may become necessary to replace the
filters. Refer to the parts list near the end of this manual for the
filter replacement kit part number.

Replacing a Fuse

1. Remove the fuse holder cover using a flathead screw
driver. Push the screwdriver into the cover and turn the
cover counterclockwise
2. Pull the old fuse out of the fuse holder cover.
3. Place the new fuse inside the fuse holder cover.
4. Place the new fuse and the fuse holder cover into the
fuse holder. Turn the fuse holder cover clockwise with the
flathead screwdriver to lock it into position.