Remedy in case of faults

Type of malfunction
A. Restricted air flow or no air flow
B.
Filter warning light is on
C.
The turbine has no power
D.
Excessive arcing/sparking in the
turbine

Technical data

Voltage:
Max. current consumption:
220~240 V AC
100~120 V AC
Acceptance capacity:
220~240 V AC
100~120 V AC
Max. air ram pressure:
RPM:
Weight:
Mains cable:
Container capacity:
Air hose:
Nozzle set:
Max. permissable
coating temperature:
Typical coating flow rate:
Max. noise level:
Turbo blower
Paint spray gun
* Measuring location: 1 m in distance from the unit 1.60 m
above the floor, reverberant floor.
** Measuring location: 2.5 m distance from the unit 1.60 m
above the floor.
8500
Possible cause
1. Air flow adjustment knob on the
spray gun is turned off
2. Air filters are clogged
1. Air filters are clogged
1. No power at the power supply
2.
The fuse is blown
3.
Worn turbine brushes
1.
Worn turbine brushes
2.
Damaged commutator
220-240V~, 50/60 Hz or
100-120V~, 50-60 Hz
7,5 A
10 A
1450 W
1125 W
0.55 bar
21 000 RPM
15 kg
3 m
1 l
9 m
No. 3, (1.3 mm)
43º C
0,35 l/m
73 dB (A)*
76 dB (A) **
GB
Measures for eliminating the malfunction
1. Adjust the air flow adjustment knob
2. Clean or replace the filters
1. Clean or replace the filters
1.
Check the power supply
2.
Check and replace the fuse
3.
Have the brushes replaced at an authorized Titan
service center
1.
Have the brushes replaced at an authorized Titan
service center
2.
Replace the turbine (contact a Titan service
technician)