8.3.3 Fischer anchor
fischer anchor
typ of dowel
drilling depth (mm)
min.anchorage depth (mm)
thickness of concrete (mm)
diameter of bore (mm)
thickness of the lift-piece (mm)
turníng moment (Nm)
Total length (mm)
Thread
piece number
It is possible to use equivalent safety-dowels (with license) of
other manufacturer but observe their regulations.
OPI-POWER LIFT HDL 6500 SST DG-7000 SST DG-8000 SST DG - HYMAX H 6500 DG-H 7000-V1.0-DE-EN-FR-ES-IT
Marking the
anchoring
depth
subject to alterations!
2.65 HDL SST
2.70 HDL SST
2.80 HDL SST
FH 24/100 B
Order No. 970267
t
255
d
h
125
ef
c
see current founda-
tion-diagram draw-
ing
d
24
0
t
0 – 100
fix
M
120
D
I
272
M
M16
a
4
b
8
c
10
d
12
e
16
f
20
g
14