About Power Lamp - Hitachi CG 36DL Mode D'emploi

Masquer les pouces Voir aussi pour CG 36DL:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
English
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or the
rechargeable battery.
Before
charging
While
charging
The pilot lamp
lights or blinks
Charging
in red.
complete
Charging
impossible
The pilot lamp
Overheat
lights in green.
standby
(2) Regarding the temperatures of the rechargeable battery
The temperatures for rechargeable batteries are as
shown in Table 2, and batteries that have become hot
should be cooled for a while before being recharged.
Table 2 Recharging ranges of batteries
Rechargeable batteries
BSL3620
(3) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown in
Table 3.
Table 3 Charging time (At 20°C)
Charger
Battery
BSL3620
NOTE
The charging time may vary according to temperature
and power source voltage.
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger fi rmly and pull out the battery.
NOTE
After operation, pull out batteries from the charger fi rst,
and then keep the batteries properly.
How to make the batteries perform longer
(1) Recharge the batteries before they become completely
exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery. If
you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
18
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
Blinks
seconds. (off for 0.5 seconds)
Lights continuously
Lights
Lights for 0.5 seconds. Does not light for 0.5
Blinks
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
Flickers
seconds. (off for 0.1 seconds)
Lights continuously
Lights
Temperatures at which the
battery can be recharged
0°C – 50°C
UC36YRSL
Approx. 60 min.
Table 1
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after use.
If such a battery is recharged immediately after use, its
internal chemical substance will deteriorate, and the
battery life will be shortened. Leave the battery and
recharge it after it has cooled for a while.
CAUTION
◯ If the battery is charged while it is heated because it has
been left for a long time in a location subject to direct
sunlight or because the battery has just been used, the
pilot lamp of the charger lights up green. In such a case,
fi rst let the battery cool, then start charging.
◯ When the pilot lamp fl ickers in red (at 0.2-seconds
intervals), check for and take out any foreign objects in
the charger's battery connector. If there are no foreign
objects, it is probable that the battery or charger is
malfunctioning. Take it to your authorized Service
Center.
◯ Since the built-in micro computer takes about 3
seconds to confi rm that the battery being charged with
UC36YRSL is taken out, wait for a minimum of 3 seconds
before reinserting it to continue charging. If the battery
is reinserted within 3 seconds, the battery may not be
properly charged.

ABOUT POWER LAMP

The power lamp indicates various statuses for the tool.
(Fig. 5)
Table 4 shows the various statuses indicated by the power
lamp.
State of lamp
Off
Red
Blinking red
Quickly blinking red
Malfunction in the
battery or the charger
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
Table 4
Status of Tool
Power OFF
Power ON
The lever is being pressed while
the overload protection circuit of
the tool is operating.
The tool is operating abnormally.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cg 36dllCg 36dalCg 36dall

Table des Matières