8. Operation

Wear glasses when using the unit.
Wear gloves and suitable clothing
when using the unit.
Safety boots must be worn.
WARNING
This machine has been designed for
use with the cleaning agents supplied
or recommended by the supplier

8.1. Start/Stop (change, rinse, foam, des)

Start mainstation
1. Check that water- and air supplies for the system
are open.
2. Make sure that the water and air supply to the
unit is open. For air see drawing 110005288-
page 14.
3. In case of central chemical supply this must be
activated too.
4. Select requested function. Use the unit according
to the "user guide".
Stop mainstation
1. Press "
" to stop program if running.
2. Turn off the water supply
3. Close the air supply
4. Deactivate chemical supply by pulling up the suc-
tion hose or removing the User Pack.
It is important to shut off the water and
air when the unit is left after use .
If the air supply is open when the unit is not in use, air
may seep into the water pipe. If this is the case the
system may have to be bled again.
It may be necessary to bleed the pipes and the unit
again after it has been closed for a longer period of
time (holidays, and the like)
CAUTION
The chemical supply must always be
rinsed thoroughly after use.
The following procedure will clean the chemical sup-
ply for detergents and/or remains of disinfectants:
1. Remove User Pack or standard can.
2. Hold the rinsing bottle with clean water tightly
against the suction opening (with User Pack).
Alternatively, you can place a User Pack with
clean water in the holder or – without User Pack
– place the hose in a bucket of clean water.
3. Activate the hose handle until clean water comes
out of the nozzle (approx. 30 seconds).

8.2. Long stops

If long productions stops are planned (more than 6
months) and the pump is emptied of water, it is rec-
ommended that the pump be secured as follows:
1. Remove the coupling safety guard.
2. Spray a couple of drops of silicone oil onto the axle
110005290
between the top section and the coupling.
Carefully follow the instructions given in the manual
provided by the pump supplier. Never store or install
the equipment where the ambient temperature gets at
or below the freezing point.

8.3. Regular maintenance

Only use original spare parts.
Quick coupling; it is recommended to lubricate all
coupling parts regularly, approx. once a month) by
waterproof grease to prevent leaks and damage of
o-rings.
1. If the quick couplings leak, o-rings should be
replaced.
2. Depending on usage, maintenance should be
undertaken by an authorised service engineer at
least once a year in order to prevent defects and
failure of operation. Authorised engineers are
persons who due to their skills and experience
have sufficient knowledge of Hygiene Systems
and are confident with the state work safety regu-
lations, accident preventing regulations, lines and
generally acknowledged technical regulations
such as DIN-norms and VDE-provisions. For
your safety, this cleaning unit has been manufac-
tured according to all relevant regulations valid
in the EU and therefore it has been supplied with
the CE-marking. For further information, please
refer to the service department.
3. When the cleaning process has been completed
or chemicals have been changed, it is important
to rinse the suction and injector system in the
following way:
• Replace the can with a can containing clean
water.
• Put the suction hose into the water can.
• Connect the foam nozzle.
• Open the spray gun/outlet valve and keep it
open until the injector has been rinsed through
(approx. 30 seconds).
Remove the suction hose from the water can.
4. It is recommended to delime the unit according to
pharagraph 9.6
21