Ecolab Hybrid Foamatic MA2CM Mode D'emploi page 156

Table des Matières

Publicité

Description of internal valves in Hybrid Foamatic SA/MA
Description of sequence for wash steps
Rinsing
Sequence
1
2
3
4
5
6
7
Foaming
Sequence
1
2
3
4
5
6
7
8
9
10
11
12
Sanitize
Sequence
1
2
3
4
5
6
7
8
9
Pause
Sequence
1
Injector pulse flush function
Sequence
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
156
Activity/function
Activate area valve*
Activate rinse valve (Q110)
Step time – rinsing
Deactivate rinse valve (Q110)
Action pause (closing of valve)
Deactivate area valve
Action pause (close of vave)
Activity/function
Activate area valve*
Activate product water valve
Activate chemical product valve**
Action pause
(opening of valve)
Activate air valve
Step time – foaming
Deactivate air valve
Deactivate chemical product valve**
Deactivate product water valve
Action pause (closing of valve)
Deactivate area valve
Action pause (closing of valve)
Activity/function
Activate area valve*
Activate product water valve
Activate chemical product valve**
Step time – sanitizing
Deactivate chemical product valve**
Deactivate product water valve
Action pause (closing of valve)
Deactivate area valve
Action pause (closing of valve)
Activity/function
Step time – pause
Activity/function
Activate area valve*
Activate product water valve
Action pause
(opening of valve)
Deactivate product water valve
Action pause
(closing of valve)
Activate product water valve
Action pause
(opening of valve)
Deactivate product water valve
Action pause
(closing of valve)
Activate product water valve
Action pause
(opening of valve)
Deactivate product water valve
Action pause
(closing of valve)
Activate product water valve
Action pause (opening of valve)
Deactivate product water valve
Time/valve no. to activate
XX sec.
3 sec.
3 sec.
Time/valve no. to activate
(Q111)
(Q120/Q121/Q122)
3 sec.
(Q112)
XX sex.
(Q112)
(Q120/Q121/Q122)
(Q111)
3 sec.
3 sec.
Time/valve no. to activate
(Q111)
(Q120/Q121/Q122)
XX sec.
(Q120/Q121/Q122)
(Q111)
3 sec.
3 sec.
Time/valve no. to activate
XX sec.
Time/valve no. to activate
(Q111)
10 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)
5 sec.
(Q111)