Ecolab Hybrid Foamatic MA2CM Mode D'emploi page 157

Table des Matières

Publicité

17
Action pause
18
Activate product water valve
19
Action pause
20
Deactivate product water valve
21
Action pause
22
Deactivate area valve*
Fill pipe
Sequence
Activity/function
1
Activate product water valve
2
Action pause (opening of valve)
3
Activate area valve*
4
Step time – filling pipe
5
Deactivate product water valve
6
Action pause (closing of valve)
7
Deactivate area valve*
8
Action pause
Empty pipe
Sequence
Activity/function
1
Activate area valve*
2
Activate air valve
3
Step time – emptying pipe
4
Deactivate air valve
5
Action pause (closing of valve)
6
Deactivate area valve*
7
Action pause
* Customer has to decide which area valve
** WARNING! Be sure not to open two chemical product valves at the same time!
(closing of valve)
(opening of valve)
(closing of valve)
(closing of valve)
(closing of valve)
5 sec.
(Q111)
5 sec.
(Q111)
5 sec.
Time/valve no. to activate
(Q111)
5 sec.
XX sec.
(Q111)
3 sec.
3 sec.
Time/valve no. to activate
(Q112)
XX sec.
(Q112)
5 sec.
3 sec.
157