7.2.1.

Adjustment of detergent local outlet

Remove cover from the unit.
Adjustment of detergent can be done by means of a
limiting nozzle.
The limiting nozzle is placed in the suction nipple of
the non-return valve (110003603) and can be re-
placed with a smaller or larger nozzle depending on
the concentration needed, please also see table for
guidelines.
All tests have been made with Topax 12
Nozzle size in mm
Concentration by 20 Bar in %
0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,1
1,5
7.2.2.
Insert a limiting nozzle in the top of the valve fitting on
the inlet side of the valve.
0,75
1,15
1,65
2,20
2,90
3,60
4,40
5,3
9,4
7.2.3.
xxxPD
The injector is replaced with another size as neeeded
to adjust the flow. Various sizes can be found in the
recommended spare parts.
110003603
110008142

Adjustment of detergent SAxxx

Adjustment of prediluted detergent SA-
110008143
110008157