4. Overview and use

The mainstation in the Hybrid range is a completely
functioning hygiene and pumping station that sup-
plies pressurised water to both its integrated hygiene
points (optional) and to several connected cleaning
areas. Therefore the mainstation must be supplied
with:
water in sufficient quantity, power, compressed air,
detergent(s), disinfectant.
The station is then ready for hygiene duties.
The mainstation is fittted with a frequency controlled
pump which ensures a constant working pressure
independent of usage pattern.
Warning: Do not use the water from
the system for applications other than
cleaning.
Consumptions:
The unit is approved for the use of detergents and
disinfectants.
Warning: Do not change the settings
made or recommended by the supplier
of the detergents!
Detergents are supplied via a User Pack system or
from separate standard cans. Supply is also possible
via piping systems.
Before installation and set up of the unit always read
this instruction thoroughly. Always make sure to
follow personal safety procedures for chemicals in
connection with refilling procedures (product change),
maintenance and repair. See also product label and
Material Safety Data Sheet (MSDS).
Warning: Be aware that mixing of
chemicals during use can lead to a
dangerous chemical reaction poten-
tially dangerous to the user.

Safety instructions

Only professional service personel are allowed to
carry out service and repairs on the unit.
Only instructed personel are allowed to operate the
unit.
14

5. System safety

In case of error/defect or service on equipment:
1. Close the water supply
2. Close the air supply
3. Turn of power supply

5.1. Closing valve for water supply.

With this valve the unit can be isolated from the water
supply. Further, a non-return valve is built in the unit
to prevent backflow of water.
Open

5.2. Closing valve for air supply

With this valve the unit can be isolated from the air
supply. Two non-return valves for air are built in the
unit to prevent backflow of air.
Open
The air pressure regulation/gauge only
works when the supply valve is open.
Wear glasses when using the unit.
Wear gloves and suitable clothing
when using the unit.
Warning:
The spray jets can be dangerous if
subjected to misuse. The jets must not
be directed at persons, live electrical
equipment or the unit itself.