Safety Inspection - ATT Nussbaum SMART LIFT 2.30 Manuel D'exploitation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9

Safety inspection

The safety inspection is required to guarantee oper-
ational safety of the lift. It is to be done:
1. before first commissioning after setting up the lift
Use the "single safety inspection" form
2. After first commissioning, check regularly at least
once per year.
Use the "regular safety inspection" form
3. After changes to the lift construction.
Use the "extraordinary safety inspection" form
i
Single and regular safety inspections must be
done by a specialist. It is recommended to do
maintenance at the same time.
After a change in construction (for example
i
changing the load carrying capacity or chang-
ing the lifting height) and after significant mainte-
nance on load carrying parts (e.g. welding work),
inspection by a technical expert is required (ex-
traordinary safety inspection).
This inspection book contains forms for copying to
be used for safety inspections.
Please use the appropriate form, record the condi-
tion of the inspected lift and leave the completed
form in this inspection book.
9.1
Assembly instructions capture bar fixation
for SMART LIFT 2.30 SL/HYMAX S 3000
for SMART LIFT 2.35 SL/HYMAX S 3500
for SMART LIFT 2.40 SL/HYMAX S 4000
OPI_SMART LIFT 2.30 SL-2.35 SL-2.40 SL_V3.1_DE-EN-FR-ES-IT
Tools required
1: Nail puller
2: Allen key 6 mm
3: Allen key 3 mm
1
2
3
Scope of delivery
Screw M8 2x
Guide bar 2x
Nuts 2x
Base plate 2x
Safety system SL
Lift nut
Locking nut
Latch
Capture hook
Fixing bracket 2x
123