Safety Regulations; Safety Inspection; Operating Manual; Operating Element - ATT Nussbaum HYMAX 4000 PH Série Manuel D'exploitation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4

Safety regulations

When working with systems comply with legal acci-
dent prevention regulations according to BGG 945:
Comply with inspection of lifts; BGR 500, operation
of lifts; (VBG 14).
Particular attention is drawn to compliance with
the following regulations:
• When operating the system, follow safety regula-
tions and operating instructions in the operating
manual.
• The total weight of the accepted load may not
exceed 4,000 kg,
• Only personnel aged 18 or over may operate
systems independently, they must be trained in
system operation and have their work verified by
the company. They must be explicitly tasked with
operating the system (excerpt from BGR 500), see
transfer protocol.
• During lifting or lowering, the work area of the sys-
tem should be clear or people.
• It is prohibited from moving people with the lift.
• It is prohibited to climb onto the system.
• The lift must be completely lowered before the
vehicle is driven on, and it may only be done in
the intended direction.
• For vehicles with low floor clearance or custom
equipment, check before driving, whether it
could be damaged.
• The set up of standard lifts is not permitted in fire
and explosion endangered work shops.
• Caution when leaving car engines running in en-
closed spaces: danger of poisoning.
• When removing heavy vehicle parts (e.g. motors)
the centre of mass of the vehicle changes. In this
case secure the vehicle against falling using suit-
able means.
• Initial access into the lift may only be done after
the main switch is off and locked.
• Secure the lift against unauthorised use by switch-
ing off the main switch and by using a padlock.
• Always keep the lift and work space clean and
dry.
4.1

Safety inspection

The safety inspection is required to guarantee oper-
ational safety of the lift. It is to be done:
1. Before first commissioning after setting up the lift
Use the "single safety inspection" form
2. After first commissioning, check regularly at least
once per year.
Use the "regular safety inspection" form
3. After changes to the lift system construction
Use the "extraordinary safety inspection" form
Single and regular safety inspections must be
!
done by a specialist. It is recommended to do
maintenance at the same time.
OPI_JUMBO LIFT 4000 NT_V3.0_DE-EN-FR-ES-IT
After a change in construction (for example
i
changing the load carrying capacity or chang-
ing the lifting height) and after significant main-
tenance on load carrying parts (e.g. welding
work), inspection by a technical expert is re-
quired (extraordinary safety inspection).
This inspection book contains forms with a detailed
inspection plan for safety inspections. Please use
the appropriate form, record the condition of the
inspected system and leave the completed form in
this inspection book.
5

Operating manual

When handling the system, it must
absolutely comply with safety regula-
tions. Carefully read the safety regu-
lations in Section 3 before first opera-
tion!
5.1

Operating element

1
1 Main switch
o
2
„Lift" button
u
3
„Lower" button
5.2

Lifting the vehicle

• Drive the vehicle over the drive rails lengthwise
and cross-wise in the centre.
• When driving onto the lift, position the ramps so
that the rollers (7) of the ramps (9) are on the
ground.
2
3
003
67

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nussbaum jumbo lift 4000 ntNussbaum jumbo lift 4000 nt inground

Table des Matières