Cleaning The Tank - ELMECO QK 1 Manuel D'utilisation Et De Maintenance

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

We recommend NOT to connect the machine through adaptors, multiple plugs and/or extensions. If necessary, only use
materials in accordance with the existing security laws concerning the power intensity as indicated in the plate data
(pic.4 page 22).
After connecting the machine to the electric network and switching it, verify the air flow from the side grids.
Setting temperatures scales "°C - °F"(valid for revision 16v1 and higher)
Machine comes with temperature settings set to Celsius (°C) as a default. For revision "16v1" and higher of the control
board, operator can switch between degrees Celsius (°C) and Fahrenheit (°F) by following below procedure:
1. Make sure the machine is turned off; main switch (page.22 pos. F) in OFF position
2. While holding down
when control board's screen shows
3. In order to return back to the degrees Celsius (°C), repeat what is in the previous step
Before switching the machine on, it should be cleaned properly.
Always comply with the provisions of the local authorities in charge regarding the
cleaning of the machine.
Daily clean and sanitize the machine.
Before carrying out whatever operation, switch off the machine (page 22 pos. F) and
unplug it.
Use a solution of cold water and sodium hypochlorite (bleach) with the following
proportion: 10 grams (1/2 tea spoon) for each liter of water. Rinse with warm water.
A greater quantity of bleach could damage the augers.
If the plastic parts are dishwashed, ensure the temperature is not higher than 60°C or
140°F, because they could be damaged.
Do not use abrasive powder.
It is recommended to clean the filter at least once a week.
Cleaning is very important if you want the machine to last longer; it is therefore useful to periodically wash all parts in
contact with the product, using the following procedure:
Please see the pictures at pages 60-61 of this instruction manual:
- During the cleaning procedure, the machine must have the refrigerator system turned off. Select or the "MOTOR
ON" mode or "MODE ON" mode, see page 27;
- Use disposable gloves;
- Open the tap in order to empty the tank. Leftovers can be kept in the refrigerator, in special tanks, if allowed by the
local authorities in charge;
- Remove the cover, as illustrated in pic. 1-2-3-4-5;
- Pour water in the tank and empty it again;
- Switch the machine OFF by the main switch and unplug the power supply;
- Remove the tap from the tank as illustrated in pic.6-7-8-9;
button on the front control board, turn the machine back ON. Release
TEMP. SET IN °F
TEMP. SET IN °C
Cleaning

Cleaning the tank

- 24 -