Pressure switch and protection mode Condenser cleaning procedure
On the right side panel there is a green light (see pic.22 page 61). If it switches off, it means that the pressure switch intervened as the machine reached a high
pressure inside the cooling circuit. The pressure switch is equipped with automatic reset, when the pressures have decreased, the compressor will return to
operation and the light will come on.
A too high pressure can be caused by:
1. The machine is located close to an heating source and its internal temperature increases;
2. The air circulation is obstructed;
3. Dirty filter.
If the cause Is this last case:
Remove the filter from the rear of the machine (see pic.23 page 61);
Clean the filter with compressed air.
Clean the filtre at least once a week.
Soft Premium Cream
- selection of the functioning mode, in a cyclic sequence:
o SOFT MODE - soft mode;
o NIGHT MODE - night mode;
o MOTOR ON - Cold-Switched off;
- if the values of a parameter are changed, it scrolls horizontally between the parametrs in a cyclic sequence;
Do not wash the membrane of the electronic control with abrasive substances or cloths.
In the event that the machine is turned off, when it is turned on again, the electronic module will be positioned
on the main screen "MODE ON", see page 27.

Controls and signals

- within the menu, it means to go forward;
- within the menu, it means to go backward;
- enter the menu;
- exit the menu.
- augers switch on;
- if the values of a parameter are changed, it let you
confirm the selected value (enter) and returns to the
upper menu;
- 26 -