ELMECO QK 1 Manuel D'utilisation Et De Maintenance page 36

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

b. Press the
settings.
5. Press the
key to confirm; the display will show the third option of the SERVICE submenu.
The display will flash and show the "V3" speed at which the augers must turn once the "T2" temperature has
been exceeded. Said velocity is maintained also during the "READY TO SERVE" product maintenance stage, unless
the machine is not dispensing. The default value is: V3=30rpm
a. Press the
or
b. The"RTS" is fixed and cannot be changed; this setting corresponds to the temperature that is stored in the
electronic unit's memory when it is in "READY TO SERVE" mode.
6. Press the
key to confirm; the display will show the fourth option of the SERVICE submenu.
The display shows the time period in which the electronic unit, by controlling the temperature decrease, decides
when to change from "WAIT PLEASE" to "READY TO SERVE" mode. Although "READY TO SERVE" mode can be
seen, the solenoid valve is still active, because it is controlled by "EV OFF TIME", the fifth option of the submenu.
In "EV OFF TIME = RTS TIME" mode, the machine passes from "WAIT PLEASE" to "READY TO SERVE" and the
deactivation of the solenoid valve coincide. The default value is RTS TIME= 10min.
a. Press the
or
7. Press the
key to confirm; the fifth option of the SERVICE submenu will appear on the display.
The display shows the time period in which the electronic unit, by controlling the temperature decrease, decides
when to deactivate the solenoid valve and when to product maintenance. The default setting is: EV OFF TIME=
10min
a. Press the
or
8. On pressing the confirm key
9. Press the
key to exit the menu.
Examples of settings
V1=70rpm
T1=-3,5°C
25.7°F
When the SERVICE submenu is set according to the above table, the machine will function as follows:
When passing from "Motor On" to "Soft Mode WAIT PLEASE" mode, the augers turn at 70rpm, as long as the
temperature shown on the TANK TEMPERAT. screen is warmer than -3,5°C/25.7°F (e.g. -3,0°C/26.6°F);
key to switch to the next T2 "-8,5°C/16.7°F min. / max -2,5°C/27.5°F in steps of 0,5°C/0.9°F"
SERVICE STEP V3
V3rpm
keys to change the V3 "20 min. / max 70 in steps of 1rpm"
keys to change the 10 "03 min. / max 20 in steps of 1min." Settings.
EV OFF TIME
keys to change the 10 "min. 03 / max 20 in steps of 1min." settings.
the control panel will return to the SERVICE screen.
> SERVICE
V2=50rpm
V3=40rpm
T2=-4,5°C
23.9°F
RTS
RTS TIME
10min.
10min.
RTS time= 10'
EV off time=10'