Instructions For Maintenance; Software Instructions - BIANCHI VENDING LEI600 Manuel D'emploi Et Entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
for Maintenance

6.0 SOFTWARE INSTRUCTIONS

6.1 PASSWORD
The current programming logic requires, when entering by pressing the
PROG key, the insertion of a password allowing to access one programming
menu.
To facilitate and speed up some operations on the field, the password ma-
nagement is subdivided as follows:
PWD 1 - Reduced programming menu (00001)
PWD 2 – Sales Menu (00000)
6.2 MACHINE MENUS
PWD 1 allows the access the complete menu of the vending machine. The
menu access procedure is as follows: press PROG key on the master board,
enter the password and press ENTER key. Below is a list of programming
menus of the vending machine.
6.2.1 SOFTWARE MENUS MACHINE
IN PROGRAMMING MODE, THE KEYS HAVE THE FOLLOWING MEANINGS:
Mechanical keypad
P1
inc
P2
dec
P3
shift
P4
enter
P5
Esc
P7
In the doses selections menu: shows name of box or mixer
P10
In the doses selections menu: performs only soluble powder test
P11
In the doses selections menu: performs only water test
P12
In the doses selections menu: performs complete test
Easy Smart (Default Bianchi)
P3
inc
P4
Esc
P6
In the doses selections menu: shows name of box or mixer
P7
dec
P10
In the doses selections menu: performs only soluble powder test
P11
shift
P14
In the doses selections menu: performs only water test
P15
enter
P18
In the doses selections menu: performs complete test
Instructions
For Alphanumeric version
P1
Alphanumeric keypad
P2
Alphanumeric keypad in the Activate lift menu:
lift positions programming input
P3
Alphanumeric keypad
P5
Alphanumeric keypad
P7
Alphanumeric keypad
P9
Alphanumeric keypad
PA
Alphanumeric keypad
In the lift positions programming menu: Lift UP
PB
Alphanumeric keypad
In the lift positions programming menu: Lift DOWN
6.4 MAINTENANCE
Maintenance is performed by pressing the key 'Service'.
In line 1 "Maintenance xxx" will be displayed , where xxx displays the boiler
temperature, and in line 2 the possible detected alarms.
Pressing twice the key Service, the stand by heating phase will be bypassed,
allowing you to perform test selections even on non regimen temperatures.
Pressing a key the slave boiler temperature will be displayed in scroll.
The maintenance panel has the following functions
In the maintenance mode the keys have the following meaning:
P1
scroll alarms (if pressed for 5 seconds appear to display the last
15 alarms)
P2
reset
alarms
P3
complete test
P4
cup release
P5
group rotation
P6
spoon release
P7
column rotation
P8
grinder-doser test
P9
total entries display
P10
mdb tube filling (Easy Smart)
P11
mdb tube depletion (Easy Smart)
P12
input test
P13
test without sugar and spoon
P14
nozzle movement test (Easy Smart)
P15
decounter reset
P16
mixer test
P17
only water test
P18
Saw keypad test
P19
not used
P20
Washing syrup BIB 1 (Easy Smart)
P21
Washing syrup BIB 2 (Easy Smart)
In maintenance mode it is necessary to enter in sequence,via the alphanu-
meric keyboard, the numbers shown to obtain the desired function.
23
ENGLISH
Inc
Shift
Esc
Dec
Enter

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Lei400

Table des Matières