INSTALLATION

Installing a Remote Control Enclosure

Remote control enclosures must be mounted on the front of
the unit to ensure the controls correspond with the correct wells
(the front of the unit is the side the conduit enters under the
unit). Remote control enclosures cannot be rewired and must
be installed in the proper location.
WARNING
ELECTRIC SHOCK HAZARD: Remote control enclosure
must be mounted on vertical wall and installed in vertical
position. Mounting remote control enclosure in horizontal
position may result in collection of liquids and lead to
electric shock.
NOTE: A qualified electrician should connect the unit(s) to a
power source.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the "Control Enclosure Cutout Dimensions" chart
below for the cutout dimensions for each control enclosure.
• The cutout depth required for all control enclosures is
6-1/2" (165 mm).
• Make sure to have enough space inside the cutout if
installing with conduit on the side of the control enclosure.
• For units with two control enclosures: Each enclosure
cutout size will be different (see chart below).
2. Remove the trim cover from the control enclosure.

Control Enclosure Cutout Dimensions

Opening
Dimension
Model
Width (A)
6-5/16"
DHWBI-1
(160 mm)
10-5/16"
DHWBI-2
(262 mm)
14-5/16"
DHWBI-3
(364 mm)
18-5/16"
DHWBI-4
(465 mm)
22-5/16"
DHWBI-5
(567 mm)
26-5/16"
DHWBI-6
(668 mm)
Silicone Sealant
3/8"
(9 mm)
7/16"
(11 mm)
Opening
Dimension
Height (B)
4-3/4"
(119 mm)
4-3/4"
(119 mm)
4-3/4"
(119 mm)
4-3/4"
(119 mm)
4-3/4"
(119 mm)
4-3/4"
(119 mm)
A
D
B
C
Control Enclosure Cutout and Screw Hole Dimensions
3. Position the control enclosure into the opening through the
backside.
4. Secure the control enclosure to the mounting surface
using screws (#8 sheet metal screw supplied).
5. Connect the proper power
source to the mounted
remote control enclosure.
Wiring must be fixed a
minimum of 4" (102 mm)
from bottom of well(s).
6. Apply a 1/4" (6 mm) bead
of NSF-approved silicone
sealant where the trim cover
will contact the cabinet surface. Refer to the "Control
Enclosure Cutout and Screw Hole Dimensions" illustration
for more information.
7. Reinstall the trim cover on the control enclosure and
secure in position using the four trim cover screws. Make
sure to embed the trim cover edge into the silicone.
NOTE: Standard UL approved units are equipped with a
72" (1829 mm) flexible conduit connected to the remote
control enclosure.
Screw Hole
Dimension
Width (C)
6-9/16"
(167 mm)
10-9/16"
(269 mm)
14-9/16"
(370 mm)
18-9/16"
(472 mm)
22-9/16"
(573 mm)
26-9/16"
(675 mm)
6-1/2"
(165 mm)
1-1/2"
(38 mm)
Left Side View –
Control Enclosure
8
English
Typical knockout
locations for power
source connection.
Control
Enclosure
Screw Hole
Dimension
Height (D)
2-1/2"
(64 mm)
2-1/2"
(64 mm)
2-1/2"
(64 mm)
2-1/2"
(64 mm)
2-1/2"
(64 mm)
2-1/2"
(64 mm)
IMPORTANT NOTE:
Make sure the installation location
provides enough room for electrical
connections to the control enclosure.
Follow local and national plumbing
and electrical codes.