MAINTENANCE

General

The Hatco Modular Built-In Dry Heated Wells are designed
for maximum durability and performance, with minimum
maintenance.
WARNING
ELECTRIC SHOCK HAZARD:
• Turn power switch OFF, disconnect unit from power
source, and allow unit to cool before performing any
maintenance or cleaning.
• DO NOT submerge or saturate with water. Unit is not
waterproof. Do not operate if unit has been submerged
or saturated with water.
• Do not clean unit when it is energized or hot.
• This unit is not "jet-proof" construction. Do not use
jet-clean spray to clean this unit.
FIRE HAZARD: Do not use flammable cleaning solutions
to clean this unit.
This unit has no "user-serviceable" parts. If service
is required on this unit, contact an Authorized Hatco
Service Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350.
Do not use steel wool or metal scouring pad for cleaning.
Steel wool will scratch the finish.
Use non-abrasive cleaners and cloths only. Abrasive
cleaners and cloths could scratch finish of unit, marring its
appearance and making it susceptible to soil accumulation.
Do not use harsh chemicals such as bleach, cleaners
containing bleach, or oven cleaners to clean this unit.
Damage caused by chemicals is not covered by warranty.

Daily Cleaning

To preserve the finish of the heated well(s), perform the
following cleaning procedure daily.
1. Move the Power I/O (on/off) switches to the O (off) position
and allow the unit to cool.
2. Remove and wash any pans and adapters.
3. Wipe down the entire unit using a clean cloth or sponge
and mild detergent.
4. Use a plastic scouring pad to remove any hardened food
particles.
5. Wipe dry the entire unit using a non-abrasive, dry cloth.
NOTE: If a catch pan is used underneath the drain fitting,
make sure the pan is emptied regularly to prevent over-
flowing.
CAUTION

Monthly Cleaning

To preserve the finish of the heated well(s), perform the
following cleaning procedure monthly to remove any debris in
the well caused by spills.
1. Move the Power I/O (on/off) switches to the O (off) position
and allow the unit to cool completely.
2. Remove and wash any pans and adapters.
3. Remove the fan covers by removing the two Phillips head
screws and lifting the two covers out of the well.
4. Remove and wash the fan blade by holding the fan blade
and unscrewing the wing nut clockwise and removing the
washer (the wing nut is reverse-threaded).
5. Wipe down the entire unit using a clean cloth or sponge
and mild detergent.
6. Use a plastic scouring pad to remove any hardened food
particles.
7. Wipe dry the entire unit using a non-abrasive, dry cloth.
8. Reinstall the fan blade and the fan covers using the washer
and wing nut.
Screws
Reverse
Threaded Stud
Monthly Cleaning (Inside View of Well)
10
English
Upper Fan
Cover
Slots
Lower
Fan Cover
Wing Nut
Washer
Fan Blade
Form No. DHWBIM-0519