Installing The Control Panel Remotely; Countertop Cutout Dimensions - Hatco CWB-S Série Manuel D'installation Et D'utilisation

Cuves réfrigérées allongées libre-service
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Control Panel
Control
Panel Bolt
Rotating the Condensing Unit

Installing the Control Panel Remotely

Use the following procedure to install the control panel remotely.
WARNING
Control panel must be mounted in a vertical surface.
Mounting control panel in a horizontal surface may result
in the collection of liquids and lead to electric shock.

Countertop Cutout Dimensions

Width
Model
25-3/16"–26-1/16"
CWB-S1
(641–662 mm)
46-1/4"–47-1/8"
CWB-S2
(1175–1196 mm)
67-5/16"–68-1/8"
CWB-S3
(1710–1731 mm)
88-3/8"–89-3/16"
CWB-S4
(2245–2266 mm)
Form No. CWBSM-1120
Vertical
Upper
Support
Support
Bolt
Bracket
Vertical
Support
Condensing Unit
rotated 90°.
Hoses removed for clarity.
Depth
(A)
(B)
17-1/16"–17-15/16"
(433–456 mm)
17-1/16"–17-15/16"
(433–456 mm)
17-1/16"–17-15/16"
(433–456 mm)
17-1/16"–17-15/16"
(433–456 mm)
CWB-S Series Countertop Cutout Dimensions
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the "Control Panel Cutout and Screw Hole
Dimensions" chart for the cutout dimensions.
2. Remove the control box from the unit by removing the
bolts on the side of the condensing unit.
3. Remove the four trim cover screws from the control box
and remove the trim cover.
4. Remove the bracket from the control box by unscrewing
the four bracket screws.
5. Position the control box into the cutout opening from the
backside.
6. Fasten the control box to the vertical surface using four
screws (not supplied).
7. Apply a 1/4" (6 mm) bead of NSF-approved silicone sealant
where the trim cover will contact the cabinet surface. Refer
to the "Control Panel Cutout and Screw Hole Dimensions"
illustration for more information.
8. Reinstall the trim cover on the control panel and secure
in position using the four trim cover screws. Make sure to
embed the trim cover edge into the silicone.
7/16"
(11 mm)
3/8"
(9 mm)
Control Panel Cutout and Screw Hole Dimensions
NOTE: Make sure the width of the control panel cutout does
not exceed the above dimension.
A
9
INSTALLATION
Silicone Sealant
1-1/16"
(27 mm)
5-5/8"
(143 mm)
3-1/2"
(89 mm)
7-7/16"
(189 mm)
7-3/4"
(196 mm)