Installing the Remote Control Box

Use the following procedure to install the control box remotely
within 6' (1829 mm) of the connections under the shelf.
WARNING
Control box must be mounted in a vertical surface.
Mounting control box in a horizontal surface may result in
the collection of liquids and lead to electric shock.
1. Cut and drill the appropriate holes in the mounting
surface. Refer to the "Control Box Cutout and Screw Hole
Dimensions" chart for the cutout dimensions.
2. Remove the trim cover screws from the control box and
remove the trim cover.
3. Position the control box into the cutout opening through
the backside.
4. Fasten the control box to the vertical surface using four
screws (not supplied).
5. Apply a 1/4" (6 mm) bead of NSF-approved silicone sealant
where the trim cover will contact the cabinet surface. Refer
to the "Control Box Cutout and Screw Hole Dimensions"
illustration for more information.
6. Reinstall the trim cover on the control box and secure in
position using the trim cover screws. Make sure to embed
the trim cover edge into the silicone.
Silicone Sealant
7/16"
(11 mm)
3/8"
(9 mm)
7-7/16"
(189 mm)
(196 mm)
Control Box Cutout and Screw Hole Dimensions
NOTE: Make sure the width of the control box cutout does not
exceed the above dimension.
Form No. CSRM-0220
1-1/16"
(27 mm)
5-5/8"
(143 mm)
3-1/2"
(89 mm)
7-3/4"